Installation Guide

1
2
3
5
4
N
L2
PE
L1
PE
N
L
220-240 V ac
4
1
2 3
67
ELECTRICAL CONNECTION HARD WIRING THE OVEN
89
Rating plate
SECURE THE OVEN TO THE CABINETRY
Unhook to
open cover
Unscrew
Terminate
wiring correctly
Cable clamp
We recommend that the outlet for the power supply cable is located in the right rear corner of
the cabinet cavity. This allows the power supply cable to sit inside the right rear of the oven and
prevents it being jammed between the cabinet wall and the rear of the oven.
Connecting the oven to the
mains power supply
Important!
This oven must be connected to the
mains power supply only by a suitably
qualified person.
This oven must be earthed.
Before connecting the oven to the
mains power supply, check that
the domestic wiring system is suitable
for the power drawn by the oven
(as specified on the rating plate)
the voltage corresponds to the value
given on the rating plate.
Important!
To connect the power
supply cable DO NOT
unscrew the screws fixing
the cover plate behind the
terminal block.
124 lb
56 kg
WARNING!
Very Heavy
Do not attempt to lift this
product unassisted.
Lifting unassisted may
cause serious injury.
OB90 - NZ AU GB IE
220-240 V 4730 W (20.56 A)
REFIT THE DOOR
(1,2) -2- 599790H OB60&OB90 installA2 NZGB.indd 25/09/17 12:33 PM