Installation Guide

pppy y p
Make sure that the isolating switch will be easily accessible by the customer.
Do not stand on the door, or place heavy objects on it.
Do not lift the oven by the door handle.
Take extra care not to damage the lower trim of the oven. We suggest you place the unpacked oven onto
wooden blocks or similiar supports.
When handling the oven, take care not to damage the door sensor lever
(near the top right corner of the oven seal).
Use easy-to-clean finishes for the wall surfaces surrounding the oven, so that cooking fume staining
resulting from using the oven is easy to remove.
2
g
the oven door can open fully without obstruction.
a suitable isolating switch providing full disconnection from the mains power supply (under overvoltage
category III conditions) is incorporated in the permanent wiring, mounted and positioned to comply with
the local wiring rules and regulations. The isolating switch must be of an approved type and provide a 3
mm air gap contact separation in all poles (or in all active [phase] conductors if the local wiring rules allow
for this variation of the requirements).
the electrician provides sufficient free length of power supply cable to reach from the bottom rear of the
cavity to at least 1.5 metres in front of the bottom edge of the opening. The cable may enter the cavity
from the side, top or bottom, but top entry must be at the rear of the cavity.
PRODUCT DIMENSIONS
A
B
C
E
F
G
H
Product dimensions (mm)
OB90
models
A
overall height of product (including upper and lower vents) 478
B
overall width of product 895
C
overall depth of product (excludes handle and dials) 564
D
height of chassis at the rear 464
D
I
overall height of chassis 468
E
maximum width of chassis 853
F
depth of chassis 544
G
depth of oven frame and control panel (excludes handle and dials) 20
H
depth of oven door (open) (measured from front of door) 418
Note: If installing a cooktop above the oven, ensure adequate clearance is provided for the cooktop as per the
cooktop manufacturer’s instructions.
B
D
C
A
Installation diagrams for illustration purposes only
B
I
D
I
Ensure the cavity is completely sealed with no gaps
Cabinetry dimensions (mm)
OB90
models
A
minimum inside depth of cavity 550
B
minimum inside width of cavity 860
B
I
overall width of cabinetry 900
C
height of cavity 480
3
CABINETRY DIMENSIONS
G
16-20 mm
2.5 mm
(2,1) -2- 599790H OB60&OB90 installA2 NZGB.indd 25/09/17 12:33 PM
(2,1) -2- 599790H OB60&OB90 installA2 NZGB.indd 25/09/17 12:33 PM