Installation Guide
7
6 CAVITY PREPARATION
min. 7 7/8” (200 mm)
max. 17 11/16” 
(450 mm)
Water Connection
Recommended HOT 
(Maximum 140°F/60°C).
Supplied hose to 
suit 3/8” (9 mm) male 
compression fitting. 
Water Pressure
Water softener models
Max. 1 MPa (145 psi)
Min. 0.1 MPa (14.5 psi)
Models without water softener
Max. 1 MPa (145 psi)
Min. 0.03 MPa (4.3 psi)
IMPORTANT!
The power outlet must be 
located in a cabinet adjacent 
to the dishwasher cavity. 
110-120 VAC max. 15 A
Service Holes
Can be located either side of dishwasher, close to the rear face and the shelf, 
as illustrated.
O
If the hole is through wood, make sure its edges are smooth androunded.
O
If the hole is through metal, ensure you fit the supplied Edge Protector to 
prevent damage to the power cord.
These marks indicate formed 
bracket screw locations, if 
securing by drawer removal.
If there is no side partition, you 
can construct timber bracing 
as something to secure into.
Moisture 
protection tape 
must be applied
3/8” 
(10 mm)
COUNTERTOP
WARNING!
Incorrect placement of the hole 
will result in damage to hoses.
Max 1/2” (10 mm)
Max distance between 
hole edge and shelf
Max 1/4” (5 mm)
Max distance 
between hole edge 
and rear inner face
Ø max. 1 1/2”  
(38 mm)