Installation Guide

11
VENTING PREPARATION
VENTING TO THE SIDE
VENTING TO THE REAR
Through same cabinetry
z
This can be acheived using the supplied components. When ducting is centred below
cooktop, a maximum venting height of 1067mm* is possible, alongside a maximum venting
depth of 93mm***. These distances can be extended by using accessory kit D1-C-222-89.
When ducting is directly below the outlet, a maximum venting height of 847mm* is possible,
alongside a maximum venting depth of 93mm***.
z
A space of 105mm is required at the rear of the cabinetry to house the vertical ducting
components**. Alternately, if vertical ducting is to pass through any shelving, ensure a
cutout of 232mm x 100mm has been created in all shelves.
z
Every 3m or additional bend drops extraction performance by 2%.
Through adjacent cabinetry
z
This can be achieved through the use of a minimum of 2x E90-H-222-89 and 1x D1-C-222-89
accessory kits.
z
A space of 105mm is required at the rear of the cabinetry to house the vertical ducting
components**. Alternately, if vertical ducting is to pass through any shelving, ensure a
cutout of 232mm x 100mm has been created in all shelves.
z
Every 3m or additional bend drops extraction performance by 2%.
Through sub-floor
z
This can be achieved through the use of a minimum of 1x D1-c-222-89 accessory kit.
z
A space of 105mm is required at the rear of the cabinetry to house the vertical ducting
components**. Alternately, if vertical ducting is to pass through any shelving, ensure a
cutout of 232mm x 100mm has been created in all shelves.
z
Every 3m or additional bend drops extraction performance by 2%.
Direct from outlet
z
This can be achieved through the use of a D1-C-222-89 accessory kit.
z
When venting directly back from the outlet, the top of the ducting will sit 80mm below the
cooktop glass.
z
Every 3m or additional bend drops extraction performance by 2%.
z
This can be achieved through the use of a minimum of 2x E90-H-222-89 and 1x D1-C-222-89
accessory kits and can be configured via the front or the rear.
z
A space of 105mm is required at the rear of the cabinetry to house the vertical ducting
components**. Alternately, if vertical ducting is to pass through any shelving, ensure a
cutout of 232mm x 100mm has been created in all shelves.
z
Access through the base of the cabinetry to connect ducting components is recommended.
z
Every 3m or additional bend drops extraction performance by 2%.
*From underside of glass to base of outlet
**When vertical ducting is housed within cabinetry only
***From rear edge of glass to end of ductAll dimensions are in mm
ISO: VENTING TO REAR
PROFILE: SEPARATE HOUSING PROFILE: SHELVING
105
100
65 35
72 33
Rear edge
of cutout
Rear edge
of cutout