Installation Guide
ELECTRICAL CONNECTION
Before connecting the cooktop to the mains power supply check that:
z
The domestic wiring system is suitable for the power drawn by the cooktop.
z
The voltage corresponds to the value given in the rating plate.
z
The power supply cable sections can withstand the load specified on the rating plate.
MODEL MAX. CURRENT DRAW MAX. LOAD VOLTAGE
CGI603D* 16A 3700W 220-240V 1N ~
CGI905D 30A 7000W 220-240/380-415V 2N ~
PE
1
2
3
4
5
PE
1
2
3
4
5
N
L
N
L
1 L2
PE
1
2
3
4
5
N
L
1 L3L2
PE
1
2
3
4
5
N
L
220-240V~
PE
1
2
3
4
5
PE
1
2
3
4
5
N
L
N
L
1
L
2
PE
1
2
3
4
5
N
L
1
L
3
L
2
PE
1
2
3
4
5
N
L
380-415V~
CGI905D SINGLE PHASE CONNECTION
CONNECTION LOCATIONS CGI905D TWO-PHASE CONNECTION
CABLE CONNECTION
Connect the cooktop to the power
supply and attach the duplicate data
label to an accessible location.
*The CGI603D comes supplied with a cable. This must be wired into a suitably rated plug, permanent
connection outlet or power isolator
CG905D models
CGI905 models must be both plugged
in and hard-wired to allow use of the
induction and gas cooking surfaces.
CG603D models
Both supplied cables must be plugged
in to allow use of the induction and gas
cooking surfaces.
induction cable gas cable junction box gas cable
BASE BASE
18