Installation Guide
7
FRONT
ISO
5 CLEARANCE DIMENSIONS
A
I
B
C
E
H
D
F
G
A
I
B
C
E
J
H
D
F
G
CLEARANCE DIMENSIONS
CG604DX CG905DX
mm mm
A
Minimum clearance from left edge of cutout to nearest combustible surface
130 130
B
Minimum clearance from right edge of cutout to nearest combustible surface
115 115
C
Minimum clearance from rear edge of cutout to:
Nearest combustible surface
Nearest non-combustible surface
160
45
160
45
D
Minimum height of non-combustible material when used on adjacent walls
150 150
E
Minimum clearance from cooktop surface to:
Rangehood
Any other overhead exhaust fan
Downward facing combustible surface
Downwards-facing tiled or fire resistant surface
650
800
650
500
650
800
650
500
F
Minimum clearance below top of benchtop to:
Combustible surface
Fisher & paykel oven or nearest non-combustible surface
70
65
70
65
G
Minimum distance from right edge of cooktop to gas connection point on wall (if using a flexible hose)
250 250
H
Distance from floor to gas connection point on wall (if using a flexible hose)
min. 800 -
max. 850
min. 800 -
max. 850
I
Maximum overall depth of overhead cabinetry
600 600
J
Minimum cleance from the cooktop surface to overhead cabinetry
366 366
Note: Ensure there is an earthed power outlet within 900 mm of the centre rear of the product. The gas connector on the wall should be 800-850 mm (H) above the floor and to a distance of at least 250 mm (G) outside the
width of the product, on the right-hand side. It should be accessible with the product installed.