Installations Instructions

6
!0 FIT CLAMPING BRACKETS BASED ON THE COUNTERTOP THICKNESS & SECURE TO COUNTERTOP
!1 GAS CONNECTION
GAS
ON
GAS
ON
1
2
Fibre washer
Floating nut
Elbow (½ BSP external thread)
Foam Tape
Adhesive side
20 mm
50 mm
+50 mm
NG
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
Make sure to t the supplied
washer and regulator.
Adjust to obtain a test point
pressure of 1 kPa with the two
semi-rapid burners operating at
highest setting.
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 5 CLEARANCE DIMENSIONS.
The hose assembly must be with an Rp ½” (ISO 7‐1) female thread connection.
The hose assembly must be as short as practicable and comply with the relevant requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
If connecting the gas with a exible hose:
LP
recessed to 50 mm
check all connections
Make sure to t the supplied
washer and test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with
the two semi-rapid burners
operating at highest setting.
Washer
Washer
If converting to LP, see 17 'Converting to a dierent gas type'
To check that the ignition system operates correctly, light each burner by itself, then all burners in combination.
Check for a well‐dened blue ame without any yellow tipping.
If any abnormality is evident, check that the components of the burner assembly are located properly
If proper operation cannot be obtained, contact your nearest F&P Authorised Service Centre.
The cooktop must not be used by the customer until proper operation has been achieved.
yellow tiplifting o
good ame
Arrow
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut off by the customer, make sure the connection is fitted with an isolating valve
close to the cooktop.
The appliance must be isolated from the gas supply piping system by closing its individual shut-off valve during any pressure testing of the
gas supply piping system at test pressures at or less than 1/2 p.s.i. (3.5 kPa).
Maximum inlet gas supply pressure 20” W.C. (5 kPa). Minimum gas supply pressure for regulator testing 5” W.C. Natural Gas / 12” W.C LP
gas.
A manual shut-off valve must be installed in an accessible location in the gas line external to the appliance for the purpose of turning on or
shutting off gas to the appliance. (In Massachusetts, such shut-off devices should be approved by the Board of State Examiners of Plumbers
& Gas Fitters).
Gas connection to the product must use the nipple supplied with a 1/2” NPT external thread. The supplied gas pressure regulator must be
installed where it will be accessible for adjustment. The metal flexible hose used must be new, CSA or UL-approved, and must have a 1/2”
NPT external thread on one end and a 1/2” NPT one on the other
If connecting the gas with a flexible hose
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 5 CLEARANCE DIMENSIONS.
The hose assembly must be with an Rp 1/2” (ISO 7-1) female thread connection.
The hose assembly must be as short as practicable and comply with the relevant requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces (e.g. base of metal hotlplate, flue, or chassis of undercounter oven etc.)
GAS
ON
GAS
ON
PTFE
⁄ NPT
500 mm
50 mm
1
2
500 mm
25 mm
25 mm
500 mm
NG
NG LPG
LPG
20-50 mm
½ “ BSP
½ “ BSP
x 4
1
1
2
2
16-20mm
20-30mm
Fibre washer
Floating nut
Elbow (½ BSP external thread)
LPG test point adaptor (if using LPG)
min
S
A
R
min
A
F
S
REAR CLAMPS FRONT CLAMPS
40 mm
40 mm
30 mm
30 mm
30 mm
30 mm
Foam Tape
Adhesive side
Fibre washer
Floating nut
Elbow (½ BSP external thread)
NG Models
ALL Models
Make sure the connection point will be accessible with the cooktop installed.
To enable the gas supply to be readily shut o by the customer, make sure the connection
is tted with an isolating valve close to the cooktop.
Make sure to t the supplied
washer and regulator.
Adjust to obtain a test point
pressure of 1 kPa with the two
semi-rapid burners operating at
highest setting.
Ensure the hose is long enough to allow for removal of cooktop for servicing.
Make sure the connector is located as shown in step 3 CLEARANCE DIMENSIONS.
The hose assembly must be AS/NZS 1869 Class B or D certied, with an Rp ½” (ISO 71) female thread connection.
The hose assembly must be as short as practicable and comply with relevant AS 5601/NZS 5261 requirements.
The hose must not be kinked, subjected to abrasion or permanently deformed.
The hose must not be near or in contact with any hot surfaces
(e.g. base of metal hotlplate, ue, or chassis of underbench oven etc.)
If connecting the gas with a exible hose:
LPG Models
check all connections
Make sure to t the supplied
washer and test point adaptor.
Make sure the supply pressure
is regulated to 2.75 kPa, with
the two semi-rapid burners
operating at highest setting.
Washer
Washer
yellow tiplifting o
good ame
Arrow
x 4
x 4
30-40mm
40mm+
Repeat on all the other sides
- ¾ ¾- 1
(16-20mm) (20-30mm)
1
- 1½
(30-40mm)
1
½ +
(40mm+)
x 4
view from below