Installation Guide

CLEARANCES — 900MM MODELS
CLEARANCE DIMENSIONS
CG903D CG905D
MM MM
A Minimum clearance from top of trivets to:
z
Rangehood 650 650
z
Overhead exhaust fan 800 800
z
Downward facing combustible surface* 650 650
z
Downwards-facing tiled or fire resistant surface 500 500
B Minimum clearance below bench top to:
z
Combustible surface 70 70
z
Fisher & Paykel oven or nearest non-combustible surface 65 65
C Minimum clearance from cutout to nearest combustible surface 115 130
D Minimum distance from right edge of cooktop to gas
connection point on wall (if using a flexible hose)
250 250
E Distance from floor to gas connection point on wall
(if using a flexible hose)
800-850 800-850
F Minimum clearance from countertop to overhead cabinet
(not directly above the cooktop)
450 450
G Maximum depth of overhead cabinetry 600 600
H Minimum distance between overhead cabinets
(centered above cooktop)
900 900
I Minimum clearance from rear edge of cutout to nearest:
z
Combustible surface 125 160
z
Non-combustible surface 45 45
J Minimum clearance from front edge of cutout to counter front 35 35
A
H
f f
b
C
C
D
E
g
i
j
*Combustible surface definition
Any materials of a building structure or decorative structure made of wood, compressed paper,
plant fibres, vinyl/plastic or other materials that are capable of transferring heat or being
ignited and burned. Such material shall be considered combustible even though flame-proofed,
fire-retardant treated or surface-painted, or plastered.
Ensure there is an earthed power outlet within 900mm of the centre rear of the product. The gas
connector on the wall should be accessible with the product installed.
20