Bolt anchor FAZIIK / FAZ II K GS (short version)
Art.-No. Approval Nominal drill
diameter
Min.
drill hole
depth for
push-through
installation
Anchor
length
Minimum embedment
depth with respective
usable length
Thread Washer
(outer
diameter x
thickness)
Sales unit
Steel,
zinc-plated
stainless
steel
Seismic
C1/C2
d
o
h
2
l h
ef, min.
t
fix
dia. x length
Item gvz A4 ETA [mm] [mm] [mm] [mm] [mm] [mm] [mm] [pcs]
FAZ II 8/5 K 538989 538990 ■ — 8 45 60 35
1)
5 M 8 x 23 16 x 1.6 50
FAZ II 10/10 K 522108 522116 ■ C1/C2 10 65 75 40 10 M 10 x 33 20 x 2.0 50
FAZ II 10/20 K 522110 — ■ C1/C2 10 75 85 40 20 M 10 x 43 20 x 2.0 25
FAZ II 10/20 K — 522117 ■ C1/C2 10 75 85 40 20 M 10 x 43 20 x 2.0 50
FAZ II 12/10 K 522118 522122 ■ C1/C2 12 80 90 50 10 M 12 x 41 24 x 2.5 20
FAZ II 12/20 K 522119 522123 ■ C1/C2 12 90 100 50 20 M 12 x 51 24 x 2.5 20
FAZ II 10/10 K GS 522115 — ■ C1/C2 10 65 75 40 10 M 10 x 33 25 x 3.0 50
FAZ II 12/10 K GS 522121 — ■ C1/C2 12 80 90 50 10 M 12 x 41 30 x 3.0 20
1) With minimum embedment depth only for statically interdeterminate systems
Range
h
ef, min.
h
2
t
fix