Brochure

6
Single-phase windings
Three-phase windings
1-phase plus 3-phase (Panda “DVS” Dual Voltage System) winding
High performance AC windings from Fischer Panda
The 230 V 50 Hz, (120/240 V 60 Hz) single phase windings are stand-
ard for generators up to 25 kW. A three-phase version should be
considered above 12 kW, as the Panda generator permits asym-
metrical loads up to 50 % per phase. A Hybrid Power System should
also be taken into consideration for small to middle range on-board
power systems.
The 400 V AC 50 Hz, (208 V 60 Hz) three-phase winding has the
highest level of eciency and the best qualities. This winding can
also supply single-phase AC with the appropriate phase distribution.
A three-phase generator should always be chosen above 25 kW
(from Panda 30).
The “DVS” is a special version consisting of both a single-phase and
a 400 V three-phase winding. This version is only available from
Fischer Panda and without additional cost. Three-phase motors
such as compressors can be used and a separate single-phase
winding can supply the full nominal performance of the generator
without “asymmetrical load problems” on a phase. This simplies
the electrical installation.
Note: Generators with DVS windings supply only 85% of the
nominal performance compared to those with just a single or
three-phase winding.
lighting
air conditioners
compressors electric motors
ovens
boilers
ventilators
satellite receivers
lighting
satellite receivers
ovens
air conditioners