Brochure

14
“Perfect Power” iSeries generators
Fischer Panda iSeries generators take full advan-
tage of modern diesel engines designed to run at
lower speeds and meet current emission standards.
Engine speed is adjusted automatically according to
the electrical load which makes it economical to run.
These generators are ideal for powering varying
load proles.
“Compact Power” Panda / xSeries generators
These generators are tted with Voltage Control System
(VCS) or xControl which progressively controls the engine
speed. This has an enormously positive eect on the
exhaust emissions. The generator achieves up to 15 %
more eective performance than other non-controlled
generators. The voltage is adjusted with a tolerance of
±3 V in the range up to 80 % of the nominal performance.
Capacitors (used for boosting the starting current) are
tted in an external AC control box for the
standard versions of Premium Line
generators up to Panda 18.
Technical data for Fischer Panda vehicle generators
*) For inverter generators: output performance is calculated with a Cos Phi factor 0.8 up to 40 °C ambient temperature, otherwise calculate with factor 1.0 up to 50 °C.
*) For asynchronous generators (up to and including Panda 15000), the KVA is calculated with Cos Phi 0.85 for a short starting performance of inductive consumers. Oth-
erwise it should be calculated with factor 1.0. Generators above and including Panda 16 are calculated with an optional start performance with compensation or starting
current booster, otherwise it should be calculated with a factor of 1.
Panda generator
Model / type
Generator nominal performance
Voltage tolerance
Engine
manufactuter
Engine type
Displacement cm
3
No. of cylinders
Sound level [dBA]
( 7m / 3m / 1m)
for internal installation for installation under the chassis
PVMV-N (up to 30 kW) / PVM-NE (from 30 kW) PVK-U PVK-UK
HP1 HP3 DVS
230 V
1 Phase
50 Hz
400 V
3 Phase
50 Hz
230 / 400 V
1 + 3 Phase
50 Hz
Approx. capsule
dimensions
L x W x H) mm
Weight incl.
capsule (kg)
Standard
capsule type
Standard sound
Insulation
Approx. capsule
dimensions
L x W x H) mm
Weight incl.
capsule (kg)
Standard
capsule type
Standard sound
Insulation
Approx. capsule
dimensions
L x W x H) mm
Weight incl.
capsule (kg)
Standard
capsule type
Standard sound
Insulation
(kW) (kVA*) (kW) (kVA) (kW) (kVA)
Perfect Power : iSeries Panda marine generators
Panda 5000i 0-4,0 5 - - - - ±3 V Kubota EA300 309 1 54 / 64 / 68 780 x 460 x 430 120
GFK 4DS 761 x 447 x 440 140 MPL 4DS 1204 x 445 x 460 176 MPL 4DS
Panda 8000i 0-6,4 8,0 - - - - ±3 V Kubota Z482 479 2 52 / 62 / 67 760 x 515 x 609 192 GFK 4DS 780 x 530 x 620
220
MPL 4DS 1295 x 531 x 621 265 MPL 4DS
Panda 10000i 0-8,0 10,0 0-8,0 10,0 - - ±3 V Kubota Z602 599 2 52 / 62 / 67 760 x 515 x 609 195 GFK 4DS 809 x 530 x 620
242
MPL 4DS 1426 x 530 x 620 300 MPL 4DS
Panda 15000i-230V 0-12,0 15,0 - - ±3 V Kubota D902 898 3 54 / 64 / 68 910 x 515 x 619 230 GFK 4DS 910 x 530 x 600
275
MPL 4DS 1516 x 530 x 625 355 MPL 4DS
Panda 15000i-400V 0-12,0 15,0 Kubota D902 898 3 54 / 64 / 68 910 x 515 x 619 230 GFK 4DS 910 x 530 x 600
275
MPL 4DS 1516 x 530 x 625 355 MPL 4DS
Panda 25i-230 V 0-20,0 25,0 - - ±3 V Kubota V1505 1498 4 54 / 64 / 68 1070 x 650 x 690 335 MPL 4DS request
request
MPL 4DS 1715 x 534 x 691 460 MPL 4DS
Panda 25i-400 V 0-20,0 25,0 Kubota V1505 1498 4 54 / 64 / 68 1070 x 650 x 690 335 MPL 4DS request
request
MPL 4DS 1715 x 534 x 691 460 MPL 4DS
Panda 45i - -
0-36,0 45,0
- -
±3 V Kubota V2403T 2434 4 55 / 65 / 69
1412 x 660 x 880 662 MPL 4DS 1449 x 696 x 820
675
MPL 4DS
not available in this version
Compact Power : Panda / xSeries generators - 3000 rpm - 50 Hz
Panda 8000x /
Panda 8000
6,8 8,0 6,8 8,0 6,0 6,0 ±3 V Kubota Z482 479 2 52 / 62 / 67
870 x 515 x 634
230 GFK 4DS 870 x 523 x 580 279 MPL 4DS
1330 x 522 x 620
332 MPL 4DS
Panda 10000x /
Panda 10000
8,0 9,4 8,0 9,4 7,0 7,0 ±3 V Kubota Z602 599 2 52 / 62 / 67
910 x 515 x 630
240 GFK 4DS 910 x 522 x 620
290
MPL 4DS
1516 x 522 x 620
340 MPL 4DS
Panda 12000x /
Panda 12000
10,2 12,0 10,2 12,0 9,0 9,0 ±3 V Kubota D722 719 3 53 / 63 / 67
950 x 515 x 629
253 GFK 4DS 960 x 530 x 625 317 MPL 4DS
1566 x 530 x 625
370 MPL 4DS
Panda 15000x /
Panda 15000
12,7 15,0 12,7 15,0 11,1 11,1 ±3 V Kubota D902 898 3 54 / 64 / 68
1010 x 515 x 634
316 GFK 4DS 1000 x 530 x 630 365 MPL 4DS
1606 x 522 x 630
430 MPL 4DS
Panda 18x /
Panda 18
15,3 18,0 15,3 18,0 13,5 13,5 ±3 V Kubota D1105 1123 3 55 / 65 / 69
1100 x 540 x 680
415 MPL 4DS 1100 x 560 x 680 440 MPL 4DS
1736 x 560 x 680
544 MPL 4DS
Panda 24x /
Panda 24
20,4 24,0 20,4 24,0 18,0 18,0 ±3 V Kubota V1505 1498 4 55 / 65 / 69
1220 x 540 x 680
465 MPL 4DS 1225 x 542 x 684 492 MPL 4DS
1854 x 542 x 684
492 MPL 4DS
Panda 30x /
Panda 30
25,5 30,0 25,5 30,0 22,4 22,4 ±3 V Kubota V1505T 1498 4 55 / 65 / 69
1270 x 570 x 700
512 MPL 4DS 1270 x 570 x 690 530 MPL 4DS
1970 x 564 x 640
687 MPL 4DS
Panda 40 - - 37,0 43,5 - - ±3 V Lombardini LDW 2204T 2199 4 55 / 65 / 69
1398 x 650 x 780
690 MPL 4DS request
request
MPL 4DS
2000 x 950 x 800
request
MPL 4DS