Owner's Manual
Doc #1227191 (888) 820-3690
X1 MAX Installation Guide
Data-to-Data Installation (Included)
Hardwire T-Harness Installation (Sold Separately)
Serial Cable
Serial cable (4-pin) plugs into the gray port of the remote starter
FT-HRN-X1-OBD
ColorWire Type Output Configuration
Ignition Green Input (+) --
POC 1 Yellow • Aux 1
• Aux 2
• Lock/Arm
• Unlock/Disarm
• Starter Kill
(can only be set as latched)
• Single Pulse
• Double Pulse
• Latched
POC 2 Purple • Aux 1
• Aux 2
• Lock/Arm
• Unlock/Disarm
• Starter Kill
(can only be set as latched)
• Single Pulse
• Double Pulse
• Latched
POC 3 Blue • Aux 1
• Aux 2
• Lock/Arm
• Unlock/Disarm
• Starter Kill
(can only be set as latched)
• Single Pulse
• Double Pulse
• Latched
PIC 1 Pink • Pre-warn
• Instant Trigger
--
CAN Hi/Low Harness
ColorWire Type Location
CAN Hi Brown Data PIN 6 OBD Connector
CAN Low White Data PIN 14 OBD Connector
Caution: Do not insert 3A fuse
when connected to a remote start
through data.
(optional)
BLUE Port on idatastart