Company WCX Series Product Manual

FIRST CO. WCX12 SERIES SPEC
3
WCX12-AB Series
(1) SEER and capacity information are tested combination ratings and certied by
First Co. to the U.S. Department of Energy. DOE maintains a public database that
includes a complete listing of all appliance certications. To view (and search) this
listing, go to: http://www.regulations.doe.gov/certication-data/
ELECTRICAL DATA 208/230V - 1PH - 60 Hz
UNIT
MODEL
COMPRESSOR CONDENSER FAN MIN. CIR.
AMPACITY
MAX. HACR
BREAKER
LRA RLA FLA HP
18WCX12-AB 48 9.0 1.2 1/4 13 20
24WCX12-AB 58.3 12.8 1.2 1/4 18 30
30WCXA12-AB 73 14.1 2.8 1/3 21 30
CERTIFIED COMBINATION RATINGS (1)
UNIT MODEL TOTAL BTUH COOLING SEER
INDOOR
COIL
18WCX12-AB 18,000
12.0
20VOHBX
24WCX12-AB 23,800
32VOHBX
30WCXA12-AB 27,800 RBHP-21J***
PHYSICAL DIMENSIONS
UNIT MODEL A B C
LIQ/SUCT. LINE CONN.
(SWEAT)
APPROX.
SHIP WT.
18WCX12-AB
32 24 19 3/8 O.D. / 3/4 O.D. 20024WCX12-AB
30WCXA12-AB
NOTE:
Compressor start assist devices (capacitor and start potential relay) may be required
on WCX units with scroll compressors for installations with long line length, unusually
high or low ambient operating conditions, thermostatic expansion valves or any
other situation which can lead to slow o cycle pressure equalization and excessive
compressor starting problems.
NOTE:
R-410A refrigerant oil is not compatible with R-22 oil. Therefore, when R-410A
outdoor units are replacing existing R-22 outdoor units, the indoor evaporator
coil must be replaced with a new one, the coil must include an R-410A TXV, and
the interconnecting refrigerant lines ushed.
C
TOP VIEW
COIL
LIQ. & SUCT. LINE
ENTRY (1 1/2) OD K.O.)
3 3/8
1 3/4
1 3/4
1 3/4
1 3/4
2 5/8
3 1/2
6 7/8
12 1/4
14 1/8
A
B
208/230V-1PH-60Hz
(SUPPLY WIRING)
24 VOLT
(CONTROL
WIRING)
SUCT. LINE
ENTRY 1 1/2
K.O.
LIQUID LINE
ENTRY 1 1/2 K.O.
BACK VIEW
ALT. LINE SET 1 1/2
K.O. EACH SIDE AT
BACK
15 1/2
1 3/4
NOTE:
Liquid line valve is located on left side.
Suction line valve is located on right side.