User's Manual

13
Type 21
Arm-Away
Arms the system in Away mode when the zone is activated.
Pushbutton units send the user number to the central station when arming or disarming.
User code for button must be assigned.
Type 22
Disarm
Disarms the system when the zone is activated.
User code for button must be assigned.
Type 23*
No Alarm Response
Can be used on a zone when an output relay action is desired, but with no accompanying alarm (e.g.,
lobby door access).
Type 24
Silent Burglary
Usually assigned to all sensors or contacts on exterior doors and windows where bells and/or sirens are
NOT desired.
Provides an instant alarm, with NO audible indication at any keypad or external sounder, if the zone is
faulted when the system is armed in the Away, Stay, Instant, or Maximum modes.
A report is sent to the central station.
Type 77
Keyswitch
Assign to zone wired to a keyswitch.
Type 81
AAV Monitor Zone
Assign to zone connected to AAV module.
Monitors 2-way voice sessions as follows:
- When the zone is faulted, all alarm sounding and dialer reporting stops, except for fire alarms,
which immediately terminate the voice session and cause a fire report to be sent.
- When the zone is restored (session ended), sounding resumes (if bell timeout has not expired)
and reports that were stopped are sent.
Types 90-93
Installer Defined
These zone types can be programmed for various custom responses. See data fields *182-*185.
Types 92 and 93 can only be programmed via the downloader.
UL: Zone types 90-93 may not be used as fire or burglar zones in fire or UL burglar alarm installations.
*
The system can still be armed when these zone types are in a faulted condition.
Schedules
(installer code + [#] + [6] [4];
master code can only access schedules 01-16 for FA168CPS, 01-04 for FA148CP, and
events 00-07 for both controls; FA148CP supports up to 8 schedules, FA168CPS supports up to 32 schedules
)
No. Event Device No. Group No. Partition Start Time/ Stop Time/ Repeat Random
(see list below) for 01 events: for 02 events: for 04-06 events:
Days Days
(1-4) (yes/no)
enter 01-18 enter 1-8 enter 1, 2, or 3
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
Events: Master/Installer Installer Only
00 = clear event 04 = forced STAY arm 10 = display custom words 8-10
01 = device on/off 05 = forced AWAY arm 11 = periodic test report
02 = user access 06 = auto disarm
03 = latch key report 07 = display reminder
Repeat Options: 0 = none; 1 = repeat weekly; 2 = repeat every other week; 3 = repeat every third week; 4 = repeat every fourth week