How to Guide

12
Using the Silence Feature (Continued)
When the Smoke Alarm is Silenced When the CO Alarm is Silenced
The Smoke Alarm will remain silent for up to
15 minutes, then return to normal operation.
The CO Alarm will remain silent for up to 4 minutes.
If the smoke has not cleared or continues to
increase, the device will go back into alarm.
After 4 minutes, if CO levels remain potentially
dangerous, the horn will start sounding again.
Weekly Testing
!
WARNING: NEVER use an open flame of any kind to test this unit. You might
accidentally damage or set fire to the unit or to your home. NEVER use vehicle
exhaust! Exhaust may cause permanent damage and voids your warranty.
!
WARNING: DO NOT stand close to the Alarm when the horn is sounding. Exposure at close
range may be harmful to your hearing. When testing, step away when horn starts sounding.
!
CAUTION: It is important to test this unit every week to make sure it is working properly.
Using the test button is the recommended way to test this Smoke/CO Alarm.
You ca n test this Smoke/CO Alarm by pressing and holding th e Test/Silence but ton on the Alarm cover until
Alarm Voice says “Testing” (typically 3-5 seconds).
During testing, you will see and hear the following sequence:
The Alarm Voice will say “Testing Alarms... The Alarm will sound and for your protection is very
loud.
This may take a few seconds
”. The LED chases Blue. The Alarm Voice will say “Testing
Smoke”. The Horn will sound 3 beeps. The LED chases and flashes Red. The Alarm Voice will say
Testing Carbon Monoxide”. The Horn will sound 4 beeps. The LED chases and flashes Red.
Next The Alarm Voice will say “Evacuate, Evacuate, there’s a Fire in the [Location,
example: “Kitchen”]”. The LED chases Red. The Alarm Voice will say “Highest carbon
monoxide level was 0 PPM”. The LED chases Blue. The Alarm Voice will then say “The
testing is complete. The test is done and you are protected”. The LED glows Green.
If the unit does not alarm, make sure it has been activated correctly, and test again. If the unit still does not alarm,
replace it immediately.