User's Manual

FZ200BS Manual VERSION 0.1.0
27
With no target device, data transmission cannot be done even if data is inputted.
To set a target device, you need to know an IEEE ADDRESS of the Device.
9-4-1. Searching for an IEEE ADDRESS of Coordinator
(1) Input “+++” through Serial port of PC while a Device operates.
With Inputting +++”, the mode of FZ200BS(Coordinator)
switches from operation mode to AT-command mode.
Data transmission becomes possible when FZ200BS is in an
operation mode. Users can control FZ200BS when the device is
in an AT-command mode.
(2) OK is output from FZ200BS, input “AT+GETLOCAL”
through Serial port of PC and press Enter Key.
(3) “COORD,001551000000000B,0000is output from the Device.
COORD : It is the Device Type of FZ200BS.
001551000000000B : It is an IEEE ADDRESS of FZ200BS.
0000 : It is a NETWORK ADDRESS.
(4) The IEEE ADDRESS “001551000000000B” is required for the target device set-up.
9-4-2. Target device set-up
Set a target device with the IEEE ADDRESS that is mentioned on the previous page.
(1) Devices in the active state, FZ200BS (router) will reset