Zigbee RS232 Serial Adapter ABOUT FZ100BS Zigbee 2006 Support RS232 Interface 4dBi Dipole Antenna Provided AT Command provided
FZ100BS Manual VERSION 0.1.0 (C) Copyright FIRMTECH Co., Ltd. 2005 All rights reserved The products and operation descriptions contained herein shall be protected by copyright law. Any part or whole of products or operation description shall not be copied, reproduced, translated, nor transformed into readable form by electronic device or machines, without prior consent in writing by FIRMTECH Co., Ltd.
FZ100BS Manual VERSION 0.1.0 FIRMTECH Co., Ltd. 2005 Room B-606, Ssangyong IT Twin Tower, Sangdaewon-dong, 442-5, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea 462-120 Homepage : www.firmtech.co.kr Marketing Inquiry : contact@firmtech.co.kr Technical Support Inquiry : techsupport@firmtech.co.
FZ100BS Manual VERSION 0.1.0 What is zigbee? 1. Features of Zigbee 1) Objectives of Zigbee : To realize Personal Wireless Communication for short distance and slow speed with Low Power consumption and Low Cost, which is based on IEEE 802.15.4 Standard. 2) Frequency in Use : To use ISM(Industrial, Scientific, Medical) Band which does not require any permission to use. - 2.400 ~ 2.4835 GHz: 15 channels (No.11 ~25 channel) 3) Transmission Rate - 2.400 ~ 2.
FZ100BS Manual VERSION 0.1.0 2. Zigbee operation < Zigbee Mesh network configuration > 1) Coordinator configures the Zigbee Network. Coordinator communicates with Router and End Device. 2) Router expands Network by connecting Coordinator or other Routers. 3) End Device participates in Zigbee network and communicates with Router or Coordinator.
FZ100BS Manual VERSION 0.1.0 Products overview FZ100BS can configure Zigbee network with low power consumption and low capacity by using Zigbee stack. < Major features of FZ100BS > 1. Zigbee 2006 support 2. Mesh network support 3. Easy to input Serial data with DSUB-9 Connector. 4. Supports AT command, and control Devices by using the AT command. 5. Can check whether data is successfully transmitted or not by using ACK option. 6.
FZ100BS Manual VERSION 0.1.0 ■ List of contents IMPORTANT NOTE: ....................................................................................................................................................... 2 FCC RF RADIATION EXPOSURE STATEMENT:...................................................................................................... 2 1. PRELIMINARY USAGE OF PRODUCT.....................................................................................................................
FZ100BS Manual VERSION 0.1.0 9-5. RESET OPTION .................................................................................................................................................
FZ100BS Manual VERSION 0.1.0 1. Preliminary usage of product 1-1. Product components Model Name Pictures Q’ty FZ100BS 1EA FBA-UPC 1EA WE-2405TO 1EA CD 1EA ※ If you find any of above components is defective, or not included in the package, please contact the seller you purchased.
FZ100BS Manual VERSION 0.1.0 1-2. FZ100BS Overview (1) To configure the Zigbee network, set each device (FZ100BS) to Coordinator, Router and End Device. The initial factory set value of FZ100BS is set to Router. (2) Do not use Broadcast accompanied by a lot of traffic in the Zigbee network unless it is vital to be used. It is not recommended to make a lot of traffic in the Zigbee network because it causes lots of trouble when transmitting data and bothers to set the new route toward target devices.
FZ100BS Manual VERSION 0.1.0 (4) Coordinator and Router can configure child nodes up to 8 (5) End Devices cannot configure Child nodes Setting FZ100BS to End Devices should be prior to the Zigbee Network Configuration. If you want to change the device type of FZ100BS from Router to End Device in the Zigbee Network, you had better re-configure the whole Zigbee Network in advance. FZ100BS can configure Child nodes after they are set to Routers and participated in the Zigbee Network.
FZ100BS Manual VERSION 0.1.0 (6) FZ100BS can configure the Zigbee Network up to 4 Depth. (7) FZ100BS configures the Zigbee Network with one Coordinator. (8) FZ100BS can transmit data by multipath because it supports mesh network. Contribute the Zigbee Network which has multipath. (9) If you input Serial data into FZ100BS, It transmits the Serial data to its target device. (10) FZ100BS has 3 STATUS LED for showing the status of the Device.
FZ100BS Manual VERSION 0.1.0 (12) FZ100BS has an IEEE ADDRESS and a NETWORK ADDRESS. 64 Bit IEEE ADDRESS is a physical address of FZ100BS. Every device has its own IEEE ADDRESS and the IEEE ADDRESS is not changeable. FZ100BS set target devices by using IEEE ADDRESS. In conclusion, “target device set-up” is an inquiry using IEEE ADDRESS for NETWORK ADDRESS of its target devices FZ100BS has a 16 Bit of NETWORK ADDRESS for the Zigbee Network communication.
FZ100BS Manual VERSION 0.1.0 ※ < Routing table update of FZ100BS > Routing table is assigned to each FZ100BS after the Zigbee Network Configuration. Below is the Zigbee network status when data is transmitted from Router2 to Router1 to Coordinator. Data is input into Router2, the Router2 transmits the data to Router1, and then the Router1 transmits the data to Coordinator.
FZ100BS Manual VERSION 0.1.0 2. Product Performance Part Specification Zigbee Spec. Zigbee 2006 Specification Support Communication Distance 120 M Frequency Range 2.4 GHz ISM Band Sensitivity -98 dBm Transmit Power 9.89 dBm Size 31 (Width) X 68 (Length) X 16 (Height) Input Power DC 5V Current Consumption 60mA (Max) Operating Temperature -20 ℃ - +50 ℃ Max Operating Temperature -40 ℃ - +85 ℃ Data rate 250Kbps Antenna External Dipole Antenna (4.
FZ100BS Manual VERSION 0.1.0 4. FZ100BS Image & Dimension 5.
FZ100BS Manual VERSION 0.1.0 6. Set value of Product Part Set value Device Name FZx00 Vx.x.
FZ100BS Manual VERSION 0.1.0 7. Zigbee network Configuration To configure the Zigbee Network, set up a FZ100BS DEVICE. The following is a procedure for FZ100BS Set-up using Serial communication (HyperTerminal) Program. The signal speed of FZ100BS is basically 115200bps. 7-1. Serial Communication (Hyper Terminal) Program Execute Select [Start][All Programs][Accessories][Communication][Hyper Terminal] in order, and then a window for Connection Set-up comes up.
FZ100BS Manual VERSION 0.1.0 Select each blank as below “Bit/sec: 115200, data Bit: 8, Parity: None, Stop Bit: 1, Flow Control: None”, and click the OK button. Hyper Terminal is executed. Hyper Terminal simply does not show any letters inputted. If you check on “Display the letters inputted on the Terminal” to get to know what letters are inputted, the Recommends between FZ100BS and Hyper Terminal are mixed up. Do not check this.
FZ100BS Manual VERSION 0.1.0 7-2. Set-up FZ100BS Device Type Zigbee Device is classified as Coordinator, Router, and End Device by objective of its operation. There should be Coordinator in the Zigbee Network. A Coordinator should exist in a Zigbee Network. Coordinator manages the Network in the Zigbee Network. Router extends the Network in the Zigbee Network. End Device participates in the zigbee Network using low power consumption.
FZ100BS Manual VERSION 0.1.0 7-2-1. FZ100BS End Device Set-up (1) The Initial set value of FZ100BS is ROUTER. (2) Connect Device to PC, execute Hyper Terminal, and approve the power to the Device. “ROUTER START ERROR” is output through Serial port. “ROUTER START” and “ERROR” are output. “ROUTER START ERROR” means that The Zigbee Network Participation is failed. “ROUTER START OK” is output if the Zigbee Network is configured. (3) Input “+++” in Hyper Terminal.
FZ100BS Manual VERSION 0.1.0 7-2-2. FZ100BS Router Set-up (1) The initial set value of Device is ROUTER. ※ The initial set value of FZ100BS is ROUTER. The following is a procedure of purposely setting Device to Router by using AT-Command. However, Device originally operates as Router without intentional setting. (2) Connect FZ100BS to PC, execute Hyper Terminal Program, and approve the power to the FZ100BS. “ROUTER START ERROR” is output through Serial port. “ROUTER START” and “ERROR” are output.
FZ100BS Manual VERSION 0.1.0 7-2-3. FZ100BS Coordinator set-up (1) The initial set value of FZ100BS is ROUTER. (2) Connect FZ100BS to PC, execute Hyper Terminal Program, and approve the power to the FZ100BS. “ROUTER START ERROR” is output through Serial port. “ROUTER START” and “ERROR” are output. “ROUTER START ERROR” means that the Zigbee Network participation is failed. “ROUTER START OK” is output if the Zigbee Network is successfully configured. (3) Input “+++” into Hyper Terminal.
FZ100BS Manual VERSION 0.1.0 7-3. The Zigbee Network Configuration using FZ100BS Try to configure the Zigbee Network after setting the Type for each Device. 7-3-1. The Zigbee Network configuration Coordinator leads the Zigbee Network Configuration. Coordinator manages the Zigbee Network. (1) Turn the power of the Device set to Coordinator ON. (2) “COORD START OK” is output. “COORD START OK” and “TARGET NON” are output. “TARGET NON” means that FZ100BS has yet to set its target device.
FZ100BS Manual VERSION 0.1.0 7-3-3. Zigbee Network Participation End Device participates in the Zigbee Network. End Device performs data transmission in the Zigbee Network. End Device supports Low power consumption mode. (1) Turn the Power of the Device set to End Device ON. (2) “END START OK” is output. “END START OK” and “TARGET NON” are output. “TARGET NON” means that FZ100BS has yet to set its target device.
FZ100BS Manual VERSION 0.1.0 8. FZ100BS data transmission Data transmission is possible by Devices which set its target devices after The Zigbee Network Configuration. 8-1. Target device set-up To transmit Data, setting a target device, which is supposed to receive the Data, is required in terms of the Zigbee Network using FZ100BS. With no target device, data transmission cannot be done even if data is inputted. To set a target device, you need to know an IEEE ADDRESS of the Device. 8-1-1.
FZ100BS Manual VERSION 0.1.0 8-1-2. Target device set-up Set a target device with the IEEE ADDRESS that is mentioned on the previous page. (1) Turn the power of FZ100BS ON. (2) FZ100BS outputs a message “TARGET NON”, which means that its target device is not set. (3) Input “+++” through Serial port of PC while FZ100BS operates. “OK” is output. From then, its target device set-up is possible with AT Command.
FZ100BS Manual VERSION 0.1.0 8-2. data transmission Data transmission is done in the Zigbee Network. Data is transmitted to the target device “001551000000000B” that is set on the previous page. IEEE ADDRESS of the Device which is supposed to transmit the data is 0015510000000005. (1) Turn the power of FZ100BS set to Coordinator ON. The Zigbee Network is configured by Coordinator. (2)Turn the power of FZ100BS set to Router ON. The Device participates in the Zigbee Network.
FZ100BS Manual VERSION 0.1.0 ※ Input Serial data of FZ100BS ※ After inputting the serial data, press “Enter” key. ※ 53 byte including “Enter” key is a maximum length of Serial data can be transmitted by FZ100BS ※ The Serial data sent from a Device is output through Serial port of its target device. ※ the other forms of data cannot be transmitted while the Serial data is inputted.
FZ100BS Manual VERSION 0.1.0 9. FZ100BS Management TIP Refer to the following to configure Zigbee Network properly in terms of data transmission and Controls. 9-1. FZ100BS Device Type Set-up (1) End Device Set-up Set FZ100BS to End Device before Coordinator and Router is set. (AT+SETEND) Turn the power of the FZ100BS OFF. (2) Router Set-up Set FZ100BS to Router before Coordinator is set. (AT+SETROUTER) Turn the power of the FZ100BS OFF. (3) Coordinator Set-up Set FZ100BS to Coordinator.
FZ100BS Manual VERSION 0.1.0 9-3. [Set-up] target device & Traffic Save an IEEE ADDRESS of target device by using a command “AT+SETTARGET” Reset the Device so that its target device set-up can be processed. < It is not recommended that there is a lot of traffic in the Zigbee Network. > Refer to the meanings of Traffic in terms of Zigbee Network.
FZ100BS Manual VERSION 0.1.0 Do not set target device to FFFFFFFFFFFFFFFF(Broadcast) when performing data transmission. If data is transmitted by Broadcast, all Routers in the middle transmit the data to all nodes again. The more Devices using Broadcast data exist and the more Routers in the middle exist, the more traffic is caused in the Zigbee Network. Do not use Broadcast data transmission unless it is essential.
FZ100BS Manual VERSION 0.1.0 ROUTER START OK : A Device starts as Router and the Zigbee Network is configured properly. Thus, Zigbee Network Extension and data transmission is possible. ROUTER START ERROR : A Device starts as Router, and the Zigbee Network Configuration is failed. See if there is Coordinator around. See if there is Router participated in the Zigbee Network configured by Coordinator. See if there is channel which is the same as the one Coordinator use.
FZ100BS Manual VERSION 0.1.0 OK : The message “OK” is output from FZ100BS when a Device switches its mode from operation mode to AT command mode. - Use a command +++ to make the Device switches its mode from operation mode to AT command mode. The massage “OK” is also output when a Device switches its mode from AT command mode to operation mode. - Use a command “ATO” to make the Device switches its mode AT command mode to operation mode. 9-5.
FZ100BS Manual VERSION 0.1.0 When RESET OPTION is set to be enabled with a command AT+SETRESET1, FZ100BS fails to participate in the Zigbee Network and its target device is not properly set, FZ100BS is reset. When RESET OPTION is set to be disabled with a command AT+SETRESET0, FZ100BS fails to participate in the Zigbee Network and its target device is not properly set, FZ100BS is put on standby for a handle by users.
FZ100BS Manual VERSION 0.1.