Use and Care Manual
6. SERVICING THE GENERATOR
MAINTENANCE SCHEDULE
The electrical safety may only be checked by personnel authorised for this task.
SERVICING WORK
CHECKING ELECTRICAL SAFETY
Servicing work should only be carried out by personnel qualified for this purpose.
All the works listed in the service plan are to be carried out in accordance with the
operating and service instructions for the motor.
We recommend that these works be carried out by an authorized service station.
Initial oil change should performed after first 5 hours of use. Thereafter change oil every 50
hours. Before changing oil, check for a suitable way to dispose of the old oil. Do not pour it
down into sewage drains, onto garden soil or into open streams. Your local zoning
environmental regulations will give you more detailed instructions on proper disposal.
Items marked with a “O” required advanced skill and tools, so they should be done by the
distributor.
Page 18
Maintenance Schedule
After first 5 Hours
● Change oil.
Every 25 Hours or Annually
● Check starter battery .
Every 100 Hours or Annually
● Change oil.
● Clean cooling areas.
● Replace spark plug and set gap.
Every 200 Hours
Every 300 Hours
● Replace low-prof le air cleaner element .
● Check fuel filter and clean or replace if needed.
● Clean low-profile air cleaner element .
● Check and adjust valve clearance when engine is cold.
Perform these procedures more frequently under severe, dusty, dirty conditions.
Have a Kohler portable dealer perform this service.