MSDS
KunLun TianRun KR5(Economical and high quality Gasoline  )                                          Page4of5 
Section 11        Toxicological Information 
The  information  given  is  based  on  data  available  for  the  material,  the  components  of  the 
material, and similar materials. 
Acute toxicity: 
Oral  (Rat):  Studies  available  indicate  oral  and  dermal  LD50  s  of  >2000  mg/Kg  which  is 
considered as low acute toxicity. 
Inhalation (Rat): Studies available indicate oral and dermal LC50 s of >10 mg/L which is 
considered as low acute toxicity. 
Skin contact (Rabbit): Prolonged or repeated exposure may lead to defatting of the skinand 
subsequent irritation. 
Eye contact (Rabbit): May cause redness and transient pain. 
Respiratory  tract,  skin  allergies  and  carcinogenicity:  highly  refined  base  oil  is 
non-carcinogenic in animal experiments. However, oil deposition, inflammation and oil tumor 
animals  will  produce  when  animals  are  exposed  to  high  concentrations  of  oil  mist  in  the 
respiratory  system.  Oils  in  pyrolysis  are  mixed  with  waste  oil  may  produce  polycyclic 
aromatic  compounds  or  pollutants  caused  by  bacteria.  May  cause  cancer  or  cause  severe 
respiratory damage. 
Germ cell mutagenicity: No data available 
Reproductive toxicity: No data available 
Section 12        Ecological Information 
The  information  given  is  based  on  data  available  for  the  material,  the  components  of  the 
material, and similar materials. 
Ecotoxicity: Not expected to be harmful to aquatic organisms, but potential bioaccumulate 
may cause ecotoxicity. 
Mobility: Non-volatilized liquid, no oil mist pollution to air; Low solubility and floats and is 
expected  to  migrate  from  water  to  the  land.  Expected  to  partition  with  sediment  and 
wastewater solids. 
Persistence/degradability:  The  base  oil  is  expected  to  be  inherently  biodegradable  with 
potential bioaccumulation. 
Section 13        Disposal Consideration 
Disposal Recommendations:Waste  Mineral Oils listed in HW08 of  “National Catalogue of 
Hazardous Wastes” 
Regulatory Disposal Information: Comply with local laws and regulations. If possible, should 
be  entrusted  with  the  appropriate  qualified  hazardous  waste  disposal  agency  for  product 
recycling.  Recommended  as  a  boiler  fuel  under  controlled  conditionsand  monitor  the 
emission gases harmful substances of high-temperature combustion. Airtight container stored 
and the necessary identification when temporary saves. 
Section 14        Transportation Information 
“List  of  Dangerous  Goods”(GB12268):The  product  is  not  classified  as  9  categories  of 
hazardous goods 