Brochure

FIREYE PRIMELINE PRODUCTS • 29
D-SERIES SOLID STATE BURNER MANAGEMENT CONTROLS Bulletin D-4041
FIREYE
®
Series D40-41 Burner Management Controls provide ignition and flame fail-
ure protection for manually started oil or gas burners. Plug-in Amplifier Modules per-
mit the selection of ultraviolet, repetitive self-check ultra-violet, AUTOCHECK infrared,
or rectification methods of flame detection. The control system includes a safe start
check, effective on each start. If flame signal (real or simulated) is detected, the unit
cannot be started. For increased safety and reliability, Fireye 72D1R3 AUTOCHECK
infrared amplifier (using the pulsing flame signal) and 72DUVS ultraviolet amplifier
(using a scanner shutter) check the function of the flame detecting system for com-
ponent failure during each burner firing cycle. Meter test jacks on each amplifier mod-
ule provide flame signal readout with a DC voltmeter. Flame failure response time is
four seconds (max.). When amplifier modules with T suffix are used, the flame failure
response time is reduced to one second (max.). The control provides three SPDT and
one SPNO load switches for external loads and starting circuits. Fireye D40-41 Burner
Management controls may be adapted to a simple control system or as a building
block with auxiliary devices to provide additional functions.
Note: The fireye Series D10, D20 and D30 burner management controls and pro-
grammers are no longer available. They may be upgraded to an E110 control per
the table on the following page.
PART NUMBER DESCRIPTION
70D10 Obsolete, Upgrade to an E110 control per the table on the following page.
70D20 Obsolete, Upgrade to an E110 control per the table on the following page.
70D21 Obsolete. Replace with E120 Chassis and EP260 Programmer.
70D30 Obsolete, Upgrade to an E110 control per the table on the following page.
70D40 Chassis, 120 VAC, Semi-automatic, no programmer.
70D41 Chassis, 230VAC model of 70D40.
60-1386-2 Wiring Base for surface mounting.
60-1466-2 Wiring Base for cabinet mounting.
AMPLIFIERS
72D1R1 Infrared autocheck, 2-4 second FFRT. Use with 48PT2.
72D1R1T Infrared autocheck, 1 second FFRT. Use with 48PT2.
72D1R3 Infrared autocheck solid fuel only. 2-4 second FFRT. Use with 48PT2.
72D1R3T 72D1R3 with 1 second FFRT. Use with 48PT2.
72DRT1 Flame rectification, 2-4 second FFRT. Use with 69NDI or 45CM1.
72DRT1T 71DRT1 with 1 second FFRT. Use with 48PT2.
72DUV1 Ultraviolet, 2-4 second FFRT. Use with UV1A, UV8A, UV2, 45UV3.
72DUVS1T 72DUVS1 with 1 second FFRT.
72DUVS4 UV self-check, 2-4 second FFRT. Use with 45UV5-1007, -1008, -1009.
PROGRAMMERS
71D60 Obsolete, Upgrade to an E110 control per the table on the following page.
71D61 Obsolete, Upgrade to an E110 control per the table on the following page.
71D70 Obsolete, Upgrade to an E110 control per the table on the following page.
71D80 Obsolete, Upgrade to an E110 control per the table on the following page.
71D81 Obsolete, Upgrade to an E110 control per the table on the following page.
71D90 Obsolete, Upgrade to an E110 control per the table on the following page.