User's Manual Part 2

Firetide - Reliable Connectivity Anywhere 39 January 2011
5200 Outdoor Unit Specications
Network Port
One 10/100/1000 Mbps Ethernet port with weatherproof con-
nector
IEEE 802.3, 802.3u compliant
CSMA/CD 10/100/1000 autosense
Enclosure
Cast aluminum NEMA-4X/IP66 enclosure
Six N-type antenna connectors
Weatherproof 48VDC power connector
Weight: 3.75 lbs (1.7 Kg) with bracket
Dimensions: 8.2” x 8.6” x 2” (205 x 214 x 100 mm)
Environmental Specications
Operating temperature: -40º C to +60ºC
Storage temperature: -40º C to +85º C
Included Accessories
Bracket for pole and wall mounting
AC power adapter
Three 2.4 GHz and three 4.9-5.8 GHz 3 dBi omni staging anten-
nas, for indoor and temporary use only.
5100 Indoor Unit Specications
Network Ports
10/100/1000 Mbps Ethernet port
PoE PD on Port 1
IEEE 802.3, 802.3u compliant
CSMA/CD 10/100/1000 autosense
Enclosure
Plenum-rated metal enclosure
Six RP-SMA antenna connectors
One DC power connector, 12 VDC ±15%, 3 A
One Ethernet connector
Weight: 0.9 lbs (.4 Kg)
Dimensions: 7.3” x 6.8” x 1.4” (182 x 170 x 35 mm)
Environmental Specications
Operating temperature: 0º C to +60ºC
Storage temperature: -20º C to +70º C
Included Accessories
AC power adapter
Three 2.4 GHz and three 4.9-5.8 GHz 3 dBi omni staging anten-
nas, for indoor use only.
Appendix B FWC2050 Specications
Physical Specications • Four GigE 10/100/1000 Mbps Ethernet ports with LEDs
• IEEE 802.3, 802.3u compliant
• CSMA/CD 10/100 autosense
Network Ports Enclosure • LEDs (power, 2.4 GHz, 5 GHz)
• Reset button (recessed) • Weight: 2 lb 14 oz (1.3 kg)
• Dimensions 9.4” X 5.9” X 1.6”
Power • DC Input: 12 VDC, 2.5 A
• Port 1: IEEE 802.3at compliant PoE
• External power supply: 100–240 VAC, 50/60 Hz
Environment Specications • Operating temperature: 0°C to +60°C
• Storage temperature: -20°C to +70°C
• Humidity (non-condensing): 10% to 90%
• Storage humidity (non-condensing): 5% to 95%
• Maximum altitude 15,000 feet (4600 meters)
Included Accessories • AC power adapter with cord (non-North America power cord is separate orderable item)
• Bracket for Rack Mounting
Appendix C Reset Procedure
Firetide Access Points may be reset to factory parameters. This is useful when returning a unit from eld service or in recovering a
unit you cannot communicate with. To reset a unit, apply power and wait for the unit to fully boot. This takes 60 to 90 seconds. Use
a paperclip to press and hold the reset button for 15 seconds. Wait for the units to reboot before removing power.