2.05 Specifications
Description FP 125 FP 135 FP 165
Package System Part Number 1444-0324 1444-0326 1444-0328
Power Source Weight 47.4 lb (21.5 kg) 52.9 lb (24.0kg) 58.1 lb (26.4 kg)
Power Source Dimensions HxWxD 12 x 9.75 x 17.5" ( 304.8 x 247.7 x 444.5mm)
Number of Phases 1 Ø
Frequency 60Hz
Flexible Supply Cable Size 7 ft (2.2 m) 14AWG 7 ft (2.2 m) 14AWG 7.5 ft (2.5 m) 14AWG
Supply Lead Plug Type 5-15P 5-15P 6-50P
Nominal Input Voltage
120V AC 120V AC 230V AC
Rated kVA @ 100% Duty Cycle 5kVA 6kVA 7kVA
Rated Input Current 15A (60A@40%) 15A (60A@60%) 22.5A (120A@25%)
Maximum Input Current 38A (110A@10%) 50A (120A@13%) 35A (155A@15%)
Generator Requirements # 5kVA # 6kVA # 7kVA
Supply VA @ max. output # 4.6kVA # 5kVA # 6.8kVA
Open Circuit Voltage Range 16 – 30V 16 – 32V 15 – 30V
Output Current Range 40 – 125A 39 – 135A 36 – 165A
Duty Cycle Period 10 Minutes
Number of Output Voltage Values 4
Minimum Mains Circuit to suit factory fitted Plug &
Lead (Weld Current @ Duty Cycle)
15A (60A@40%) 15A (60A@60%) 22.5A (120A@25%)
Maximum Mains Circuit to suit factory fitted Plug &
Lead (Weld Current @ Duty Cycle)
38A (110A@10%) 50A (120A@13%) 35A (155A@15%)
Wire Size Range
Steel
.023” - .030” - .035"
(0.6 - 0.8 - 0.9mm)
Stainless Steel
.023” - .030” - .035"
(0.6 - 0.8 - 0.9mm)
.023” - .030” - .035"
(0.6 - 0.8 - 0.9mm)
Flux Core
.030” - .035”
(0.8 - 0.9mm)
.030” - .035”
(0.8 - 0.9mm)
.030” - .035”
(0.8 - 0.9mm)
Table 2-1: System Specifications
The recommended time delay fuse or circuit breaker size is 20 amp. An individual branch circuit capable of carrying 30 am-
peres and protected by fuses or circuit breaker is recommended for this application. Fuse size is based on not more than 200 percent
of the rated input amperage of the welding power source (Based on Article 630, National Electrical Code)
Firepower continuously strives to produce the best product possible and therefore reserves the right to change, improve or revise the
specifications or design of this or any product without prior notice. Such updates or changes do not entitle the buyer of equipment
previously sold or shipped to the corresponding changes, updates, improvements or replacement of such items.
The values specified in the table above are optimal values, your values may differ. Individual equipment may differ from the above spec-
ifications due to in part, but not exclusively, to any one or more of the following; variations or changes in manufactured components,
installation location and conditions and local power grid supply conditions.