Product Manual
5-24
SECTION 5:
SPECIFICATIONS
CAUTION
At no time should the withdrawal rate of an individual acetylene
cylinder exceed 1/7 of the cylinder contents. If additional flow
capacity is required, use an acetylene manifold system of
sufficient size to supply the necessary volume.
OPERATING DATA
Gas Maximum Pressure Maximum Capacity*
Oxygen 150 PSI
Welding - 3" (7,62cm)
Cutting - 8" (20,32cm)
Heating - 10 MFA, 10 MFN
Acetylene 15 PSI
Hydrogen 30 PSI
Other Fuel Gases 50 PSI
* Using 3/8" I.D. (9,5 mm) Hose - 100 ft. Long or Less
WELDING NOZZLE FLOW DATA
Oxygen
Pressure
PSIG
Acetylene
Pressure
PSIG
Acetylene
Consumption
SCFH
Metal
Thickness
Tip
Size
Drill Size Min Max Min Max Min Max
Up to 1/32" 000 75 (.022) 3 5 3 5 1 2
1/16" - 3/64" 00 70 (.028) 3 5 3 5 1 1/2 3
1/32" - 5/64" 0 65 (.035) 3 5 3 5 2 4
3/64" - 3/32" 1 60 (.040) 3 5 3 5 3 6
1/16" - 1/8" 2 56 (.046) 3 5 3 5 5 10
1/8" - 3/16" 3 53 (.060) 4 7 3 6 8 18
3/16" - 1/4" 4 49 (.073) 5 10 4 7 10 25
1/4" - 1/2" 5 43 (.089) 6 12 5 8 15 35
1/2" - 3/4" 6 36 (.106) 7 14 6 9 25 45
3/4" - 1 1/4" 7 30 (.128) 8 16 8 10 30 60
1 1/4" - 2" 8 29 (.136) 10 19 9 12 35 75
2 1/2" - 3" 10 27 (.144) 12 24 12 15 50 100
3 1/2" - 4" 12* 25 (.149) 18 28 12 15 80 160
* Use Model HD310C torch and 3/8" (9,5 mm) hose.