FIRE FEATURE OPERATION
Gas pressure and type should be checked prior to use and installation.
Natural Gas: Supply pressure: Minimum 3.5” W.C.; Maximum 5.0” W.C.
Before use, test all gas connections for leaks. Do not use fire feature if there is any evidence of leaking gas. If
leaking gas is suspected, turn off main gas supply and have repaired immediately by a qualified technician.
Wind and gusty conditions will affect the flame in an unpredictable manner. if conditions exist that are not safe,
do not use the fire feature.Do not use if any part of the fire feature has been submerged under water.
Immediately call a qualified service technician to inspect the fire feature.
Never use any material that is non-porous and holds moisture, such as gravel, pebbles, river rock, etc. When
heated, these materials will cause the trapped moisture to boil and fracture unexpectedly. Heated steam cannot
easily escape since these materials are not sufficiently porous. These materials can break and cause personal
injury or damage.
Keep leaves, sticks, wood, paper, clothing, food material, and other solid fuels away from the fire feature.
Ensure that there are no objects over the top or sides of the fire feature that could interfere with safe operation.
When not in use, the fire feature must be covered at all times.
If lava rock is wet, burn the fire feature on low for 20 minutes and then on high for 25 minutes before coming
within 15 feet of the fire feature.
When the fire feature is not in use, turn off the gas valve.
Before initial start-up, it may be necessary to purge air in gas line after system installation.