Installation Sheet

38
CONTROL PANEL REMOVAL
1. Turn the control knob(s) to the OFF position and turn off the gas
supply to the unit.
2. Turn off the light switch and disconnect the power supply from the
power source.
3. Pull the control knob(s) from the stems and set aside .
4. Slowly lift away the lighted bezels to clear the valve stems, and
carefully disconnect the wires found on the back of the bezels (use
your fi ngernail). See Fig. 38-1.
5. Remove the drip trays.
6. Using a Phillips screwdriver, unscrew and remove the control panel fastener screws and washers
(located along the front face of the control panel). Retain the screws for later re-installation .
7. Remove the crank.
8. Carefully open the control panel by lifting and pulling the control panel from the frame , allowing it to
rest on the internal chain(s).
Important: When opening, take caution to not damage any wiring.
9. If wire disconnections are required, reference the wire diagram in the MODEL SPECIFICATIONS
section in this instruction manual or the wire diagram label affi xed to the inside of the control panel.
Note: Secure any disconnected wires (coming from the inside of the unit) to prevent them from falling in.
Note: Whenever reconnecting any wires, apply a small amount of dielectric grease to the male connector,
then make the connection. This will ensure conductivity and prevent moisture from affecting the
contact.
Important: During reinstallation; prior to opening the gas shut-off valve , be sure the control knob(s)
are in the OFF position.
Fig. 38-1
Bezel
installed
Bezel
removed
Carefully
disconnect
SERVICING AND CLEANING (Cont.)