Installation Manual

20
INSTALLATION (Cont.)
Place onto studs
Fig. 20-1 Install flavor grids
Fig. 20-2 Install cooking grids
A
B
Locking
ridge
LEAK TEST
Turn all burner valves to the OFF position. Turn on the
gas supply, and test at all connections for leaks using a
soapy water solution. If bubbles appear, a leak is present.
Turn off the gas and tighten at all connections. Repeat
until no leaks are present. If a leak persists, turn off the
gas supply and contact the local gas company or dealer.
NEVER USE A FLAME TO CHECK FOR LEAKS.
Once the leak test is complete, turn off the gas supply
and proceed.
INSTALL THE FLAVOR GRIDS
Place the flavor grids directly onto the studs on the
burners (see Fig. 20-1). For 540i and 650i models,
the slightly larger grids are designed to be placed
over the outside burners, and the slightly smaller
grid over the inner burner. The flavor grids allow heat
from the burners to be evenly distributed throughout the
cooking area.
INSTALL THE COOKING GRIDS
Note: Wear heat-resistant gloves if necessary.
1. Carefully place the rear of a cooking grid between
the locking ridge of the rear wall (see Fig. 20-2, A).
Then, carefully place the front of the cooking grid
onto the front grid rest of the grill (see Fig. 20-2, B).
2. Repeat for the other grids.