Installation Instructions and Owner's Manual
9
1. The outdoor grill and surrounding area MUST
remain clear of fl ammable substances such as
gasoline, yard debris, wood, etc.
2. The airfl ow through the vent space located below
the control panel must remain unobstructed.
3. When using propane gas:
a. The required ventilation openings in the
enclosure must be clear of debris. See
the PROPANE SAFETY INFORMATION
section.
b. The propane cylinder, regulator, and
rubber hose must be in a location not
subject to temperature above 125° F (51°
C).
4. The backburner, sideburner, or infrared burner
cover must be removed before using the burner.
5. The fl ames on each burner burn evenly along
the entire burner with a steady fl ame (mostly
blue). If burner fl ames are not normal, check
and clean the orifi ce and burner/venturi tubes
for insects and insect nests. A clogged tube can
lead to a fi re beneath the grill. A proper fl ame
pattern will ensure safe operation and optimal
performance. Adjust the air shutter as needed
(see AIR SHUTTER ADJUSTMENT).
6. The in-line gas valve or gas cylinder valve must
always be shut OFF when the grill is not in use.
7. The drip collector holes must be clear and
unobstructed. Excessive grease deposits can
result in a grease fi re.
8. Whenever reconnecting any wires, apply a
small amount of dielectric grease to the male
connector, then make the connection. This will
ensure conductivity and prevent moisture from
affecting the contact.
GRILL MAINTENANCE AND SAFETY INFORMATION
WARNING: NEVER cover the entire cooking or grill surface with griddles or pans. Overheating will occur, and
burners will not perform properly when combustion heat is trapped below the cooking surface.
CAUTION: NEVER spray water on a hot gas unit.
The grill serial number tag can be found affi xed to the grill body behind the control panel
(on an aluminum tag) and on the underside of the drip tray handle (on a thermal label). It
is recommended that the drip tray fi rst be removed and cleaned / emptied of its contents,
then turned over to view. The unit rating label is located inside of the control panel.
IMPORTANT
IN THE EVENT OF A GREASE FIRE, IMMEDIATELY SHUT OFF THE MAIN GAS VALVE TO THE
UNIT. KEEP THE LID OPEN AND ALLOW THE FIRE TO EXTINGUISH ITSELF. A THOROUGH
INSPECTION BY A TRAINED SERVICE TECHNICIAN SHOULD BE CONDUCTED BEFORE
FUTURE USE OF YOUR UNIT. THE SERVICE TECHNICIAN WILL CHECK THE SYSTEM FOR
GAS LEAKS AND WILL CHECK ALL ELECTRICAL WIRING FOR DAMAGE. ALL GAS LEAKS
AND WIRING MUST BE REPAIRED PRIOR TO FUTURE USE.
REV 2 - 1611101520
L-C2-435
ELECTRICAL CONNECTIONS
A 120VAC (15 AMP minimum) GFCI GROUNDED 3-wire receptacle (not included) is required within
the vicinity of the grill to provide power to the unit. The GFCI receptacle must be a WEATHER-PROOF
IN-USE COVERED RECEPTACLE.
• Observe the National Electric Code and all local codes.
• Verify proper polarity of the receptacle.
• If an extension cord is used, ensure it is a 3-wire GROUNDED cord that is rated for the power of the
equipment, and is approved for outdoor use with a W-A marking. DO NOT use 2-prong adapters.
• DO NOT TAMPER WITH THE EXTENSION CORD OR THE UNIT POWER-SUPPLY CORD.
Important: ONLY REPLACE THE OVEN LIGHTS WITH 12V / 10 WATT HALOGEN BULB(S).