Installation Instructions and Owner's Manual
11
INSTALLATION REQUIREMENTS (cont.)
SIDE AND REAR WALL CLEARANCES
For the minimum clearances between the grill and any side
or rear walls, your setup must fall within one (or more) of the
following:
A. Clearance between grill and strictly non-combustible
wall
(i.e. brick wall, see Fig. 11-1)
• The grill must have a minimum of 4" right, left, and rear
clearance from any non-combustible wall.
(To allow for proper ventilation and prevent dangerous
overheating.)
B. Clearance between grill and a protected combustible
wall
(i.e. a non-combustible wall in front of a combustible wall
to serve as a barrier. This can be accomplished by brick,
or a metal stud fi nished with non-combustible substrate,
see Fig. 11-2)
• The grill must have a minimum of 14" right, left, and
rear clearance from the protected combustible wall.
(The 4" non-combustible material plus an additional
10" clearance between the grill and protected wall.)
C. Clearance between grill and combustible wall
• The grill must have a minimum of 18" right, left, and rear
clearance from any combustible wall (see Fig. 11-3).
REV 2 - 1611101520
L-C2-435
Fig. 11-3 Clearance 'C' Diagram
Combustible
Min.
18"
(Clearance required
for right, left, and rear)
Fig. 11-1 Clearance 'A' Diagram
Non-combustible
Min.
4"
(Clearance required for
right, left, and rear)
Fig. 11-2 Clearance 'B' Diagram
Min.
14"
Non-combustible
substrate
Non-combustible 4"
Com-
bustible
(Clearance required for
right, left, and rear)