Installation Instruction

CONVERTING THE REGULATOR
1. Unscrew and remove the cap from the regulator, extracting the converter
(Fig. 7-1).
2. Remove the converter (the plastic stalk) by carefully pulling it away from
the center of the cap (it will snap out of its seating); see Fig. 7-2.
3. Turn the converter around and replace it carefully into the center of the
cap (it will snap into place). Check that you can read (at the bottom of
the stalk) the gas type the unit is set to use (Fig. 7-3).
4. Replace the unit into the regulator and screw down until snug. Do not
over-tighten.
CONNECTING THE GAS SUPPLY
1 . Run the attached fl ex connector routed under the left side of the unit
out of the enclosure and to the gas stub.
CAUTION: Use only a C.S.A.-listed stainless-steel fl ex connector. Do
not use a rubber hose or plastic hose within the enclosure
for the Searing Station; it will leak, resulting in an explosion
and/or serious injury.
2. Be sure the gas supply is off. Connect the pipe adapter fi tting supplied
with the fl ex connector to the gas-supply stub. Use pipe joint compound
that is resistant to all gasses on the pipe fi tting. Tighten the fi tting to the
gas supply and connector fl are nut securely.
Note: Pipe joint compound should not be used on flare fitting
connections.
3. Connect the fl ex connector to the adapter on the gas supply. Be sure
to tighten securely.
4. Carefully turn on the gas supply and leak test at all connections with a
soapy water solution (equal parts liquid detergent and water). If bubbles
appear, a leak is present. Turn off gas and tighten connections, turn on
gas and repeat leak test. Repeat until no leaks are detected. Never use
a fl ame to test for leaks.
POWER SUPPLY FOR IGNITION AND LIGHTED KNOB
CAUTION: Improperly connected wires will cause damage to the unit
and may result in property damage and/or personal injury.
The unit comes with a 6' wire extension to retrieve power from a separately
purchased Echelon grill. Echelon grills are equipped with power supply
boxes, which can supply power to the searing station. Alternatively; an
optional power supply box may be ordered and installed to individually
power this unit.
INSTALLATION (Cont.)
Read gas
type here
Fig. 7-3
Fig. 7-1
Regulator
Note the cap on top
Fig. 7-2
Fig. 7-4
TO GAS SUPPLY
7
L-C2-380
Rev 1 - 1401131425