Users Manual
o Optical link status: shows optical link status between master and each remote unit.
Moreover, clicking on “REMOTE LINK n” detailed monitoring data of each optical link can
be viewed: voltage, current and temperature of each optical module, transmitted and
received optical power, and alarms related to digital data recovery system. The main
window shows only general parameters:
Parameter
Range
Description
Frequency Sync
Green: Normal state /
Red: Alarm state
This indicator shows frequency synchronization
status between master and remote unit
Status
Green: Normal state
Yellow: Warning state
Red: Alarm state
This indicator summarizes the status of optical
module based in voltage, current, temperature
and optical transmitted power
Rx Detect
Green: Normal state
Yellow: Warning state
Red: Alarm state
This indicator summarizes the status of optical
reception based in received optical power and
digital data recovery system
Error Count
---
Counter that it is incremented when optical link
fails.
Rx Power
---
Shows optical received power. For reliable
optical link, RX power must be higher than
-25dBm
Software description (Remote Unit)
While software connected to digital master allows configuration and monitoring of whole system, if software is
connected to remote unit, only parameters of this unit can be viewed / modified.
Then, status screen of remote unit only shows information regarding this unit:
Confidential