Users Manual
o Optical link status: each indicator shows optical link status between digital master and
each remote unit. Clicking on “REMOTE LINK n” detailed monitoring data of each optical
link can be viewed: voltage, current and temperature of each optical module, transmitted
and received optical power, and alarms related to digital data recovery system
Remote frame: shows configuration and monitoring information of each remote unit. The frame is
divided in the following sections:
o Uplink filtering: this section shows equivalent parameters of downlink filtering of master
unit.
Parameter
Range
Description
Frequency
UL band
Uplink frequency channels. These frequencies
are derived automatically from downlink
frequencies, taking into account frequency
separation between DL and UL bands
Channel enable
Enabled / disabled
Each of 12 channels can be enabled/disabled
Bw Filter
90KHz / 45KHz /
30KHz / 20KHz /
15KHz
Bandwidth of channels filter can be independently
adjusted (if filtering is enabled)
Confidential