Users Manual

4. Reciprocally, set UL band gain adjusting output attenuator of master unit. It is recommended that DL gain and UL gain
be equal.
5. Set up squelch settings. Controls are independent in UL (for each remote) and DL (master) bands. Typical values for
UL are between -110dBm and -100dBm for squelch threshold. For DL, recommended value for squelch threshold is minimum
level received in any active channel minus 10dB.
Set Output attenuator
Check UL and DL gain for each remote
DL squelch settings
UL squelch settings
Confidential