Users Manual

RF output power
Shows instantaneous RF output power at DL band
Overload DL
This alarm indicates that Signal Booster is being
overloaded at DL band, due to very high RF input level
Comm. Error
Indicates that communication with monitoring PA Board
is lost. In this case, following three alarms will not be
available
AGC Fail
This alarms appear if output power is higher than
maximum output power (typical +37dBm) plus 3dB.
VSWR
Alarm appears if high reflected power is detected in “To
mobile” connector
Tx Power Low
Indicates that measured output power at PA output is
lower than expected according to RF input levels and
configured gains
General control frame for narrow band and dual version
o General control
General control frame
Parameter
Description
Linked UL/DL
frequencies
If 'Yes' then frequency setting in DL will also modify
UL according to frequency band split preset in
factory. If 'No' then filter frequencies can be set
independently in UL and DL.
Squelch mode
control
If this control is set to “Linked”, DL channels
without input signal (according to DL Squelch
threshold) automatically squelch related UL
channels