Users Manual

Remote Web Server option
IP Connection
Fiplex Signal Boosters use an Ethernet module and 3G Router to give TCP/IP
connectivity (webserver and SNMP Agent). In local mode, user can connect
directly a computer to the Ethernet module using the inside Ethernet cable.
In order to access to web browser, default IP addresses of Ethernet module are
detailed in the next table:
IP Address
192.168.1.10
IP Address
Network submask
255.255.255.0
Network submask
Gateway
192.168.1.2
Gateway
Computer network adapter configuration needs to be set to same network
submask and gateway. IP address can take any value in this IP range (192.168.1.11,
for instance). These addresses can be changed by user.
Web pages description
Once the Ethernet module is properly configured, user can connect to the Signal Booster,
writing IP address in URL toolbar of any web browser available in its computer. Default
URL is http://192.168.1.10.
First screen to appear is Authentication. Default login and password are:
Login
admin
Login
Password
admin
Password
Password can be changed by user, using menu described in next sections.
NOTE: in order to restore password, push the button placed close to USB Connector during
5 seconds.