Users Manual
Figure: Install the sealing cup
Replacement of Conduit connector to sealing cup
NEMA4 considerations
This device is equipped with a NEMA4 enclosure, however, to ensure the NEMA
rating, the user must have the following considerations:
1. Correct use of the Liquid Tight Conduit. In case this interface is not used, it should
be replaced with the sealing cup.
2. Sealing cups should be installed in the non-used cable glands.
3. The RF Ports should be perfectly mated.
Mounting Cabinet FCR021
The unit has available a Liquid Tight Conduit Fitting connector for ¾” tubes. The unit
as standard has the connector installed, so if the user requires to use this connector,
if available, the NFPA cables, Ethernet, DC or AC cables can be routed through this
connector.
If the is not going to use Liquid Tight Conduits, then the connector should be replaced
by the provided sealing cup.