User Manual

Safety
ALWAYS wear protective clothing, eye protection, and follow standard safety procedures when handling
corrosive or personally harmful materials.
NEVER use this flow meter with flammable or combustible liquids.
NEVER use this flow meter in a hazardous environment.
ALWAYS verify chemical compatibility with the flow meter and pump materials of construction before operation.
ALWAYS make sure the pump and hose are properly supported.
ALWAYS use a chemically compatible hose rated for the temperature of the product being pumped.
ALWAYS place pump tube in liquid before starting.
Introduction
Thank you for purchasing an FM-2000 Series electronic flow meter. The FM-2000 Series is designed to measure the flow of a fluid being dis-
pensed from Finish Thompson’s PFP, PFM, & PFV drum pumps. The meter is factory calibrated and displays information on an LCD display. In
addition, the meter can be field calibrated to improve accuracy at a given flow rate. Four AA batteries power the unit for up to one year. There
are options for materials of construction and measurement units
FM-2000 is a rate/totalizer meter – designed to measure and display both the rate of flow and the total flow.
Specifications
Maximum Working Pressure: 35-62 PSIG (2.4 – 4.3 bar)
Maximum Fluid Temperature: PFM & PFP Models = 160º F (71º C); PFV = 120º F (49º C)
Ambient Temperature Range: 32º to 110ºF / 0º to 43º C
Enclosure: NEMA 4X (IP56)
Sensor/Paddle/Axle Material: PVDF
O-ring seals: Viton
Accuracy: +/-1% of full-scale rate reading; can be field calibrated
Repeatability: +/-1% of full-scale rate reading
Power Requirements: Four standard AAA alkaline batteries (included)
Battery Life Expectancy: 1 year minimum
Maximum Viscosity: 20 cP/mPas
Maximum Specific Gravity: 1.8
Features
Easy to read eight digit LCD display
Installs quickly on PFM, PFP, PFV Series pump tubes with supplied fittings
Factory calibrated; can be field calibrated using front panel touch buttons
Minimal maintenance required
Corrosion resistant PVDF sensor with polypropylene or PVDF body, ABS electronics enclosure
Weather resistant enclosure
High accuracy· Non-volatile memory stores settings even when batteries are removed
Kit Contents:
FM-2000 Series Meter
Flow meter adapter
Discharge nut
1” NPT coupling
Hose barb adapter
1