Excessive Power Consumption
Head lower than rating
Excessive flow
Specific gravity or viscosity too high.
Vibration/Noise
Loose magnet
Drive magnet rubbing
Pump cavitating from improper suction or feed
Motor or piping not properly secured
Foreign object in impeller
Finish Thompson, Inc (manufacturer) warrants this pump product
to be free of defects in materials and workmanship for a period
of five years from date of purchase by original purchaser. If a
warranted defect, which is determined by manufacturer’s in-
spection, occurs within this period, it will be repaired or replaced
at the manufacturer’s option, provided (1) the product is submit-
ted with proof of purchase date and (2) transportation charges
are prepaid to the manufacturer. Liability under this warranty is
expressly limited to repairing or replacing the product or parts
thereof and is in lieu of any other warranties, either expressed
or implied. This warranty does apply only to normal wear of the
product or components. This warranty does not apply to prod-
ucts or parts broken due to, in whole or in part, accident, over-
load, abuse, chemical attack, tampering, or alteration. The war-
ranty does not apply to any other equipment used or purchased
in combination with this product. The manufacturer accepts no
responsibility for product damage or personal injuries sustained
when the product is modified in any way. If this warranty does
not apply, the purchaser shall bear all cost for labor, material and
transportation.
Manufacturer shall not be liable for incidental or consequential
damages including, but not limited to process down time, trans-
portation costs, costs associated with replacement or substitution
products, labor costs, product installation or removal costs, or
loss of profit. In any and all events, manufacturer’s liability shall
not exceed the purchase price of the product and/or accessories.
Section V - Warranty
Troubleshooting
General Notes:
Do not pump liquids containing ferrous metal fines.
If magnets decouple, stop pump immediately. Operating the
pump with the magnets decoupled will eventually weaken
the magnets.
Contact our Technical Service Department If you have any
questions regarding product operation or repair:
Phone: 1-800-888-3743
E-mail: techservice@finishthompson.com
No or Insufficient Discharge
Air leaks in suction piping
Pump not primed
System head higher than anticipated
Closed valve
Viscosity or specific gravity too high
Motor too large for magnet coupling rating (magnets un-
coupled)
Suction lift too high or insufficient NPSH
Clogged suction line or impeller vanes
·Motor rotation incorrect (correct rotation when viewed from
the fan end is clockwise)
Insufficient Pressure
Air or gas in liquid
Impeller diameter too small
System head lower than anticipated
Motors speed insufficient (too low) or motor rotation incor-
rect (correct rotation when viewed from the fan end is
clockwise)
Loss of Prime
Leak in suction piping
Foot valve or suction opening not submerged enough
Foot valve too small or leaking
Air or gas in liquid
Foreign matter in impeller
Leaking valve. Suction lift too high or insufficient NPSHa.
Ordering Spare Parts
Spare parts can be ordered from your local distributor. Always
refer to the pump model to avoid error.
Literarture I.D. No. FT08-1023H
Part Number 106782, Rev 12, 4-15-13