BT SERIES PUMPS BTS OPERATION & PARTS MANUAL
EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements as specified be the EC Directives listed. The product may not be taken into service until it has been established that the drive motor for the Drum and Container Pump complies with the provisions of all relevant EC Directives.
Introduction This manual pertains to the BT Series stainless steel drum pumps. Finish Thompson Inc. thanks you for choosing our products. We believe the use of our products will be fully satisfactory. When properly installed and operated, your Finish Thompson motor and pump will provide long, trouble-free service; therefore, please read this manual carefully before carrying out any operations on the pump/motor unit.
Warranty, General Terms & Conditions 1. The following terms and conditions apply to the sale of machinery, components and related services and products, of Finish Thompson Inc. (hereinafter “the products”) 2. Finish Thompson Inc. (the manufacturer) warrants only that: a) its products are free of defects in material, design and workmanship at the time of original purchase; b) c) its products will function in accordance with Finish Thompson Inc. operation manuals; Finish Thompson Inc.
Safety 1. Introduction This manual contains all the information needed for the correct installation, use and maintenance of your new Finish Thompson pump. It should be read and understood by all the personnel involved in installation, operating and servicing of the pump before it is started. 2. Operator Qualification and Training The personnel in charge of the installation, the operation, and the maintenance of the pump must be qualified and able to perform the operations described in this manual.
PUMP SPECIFICATIONS MODEL BTS Outer Tube Diameter 2” (5.1 cm) Discharge Thread 1-1/2” hose barb Max. Specific Gravity 1.8 Max. Viscosity 15,000 cP -20°F Min. to 200°F Max. Min./ Max. Fluid Temperature (-29°C Min. to 93°C Max.
Installation & Maintenance Instructions Installation 1. Remove the drum pump and motor from its packaging and inspect for shipping damage. 2. Turn the pump coupling to verify there is no binding. 3. Adjust the coupling so that the empty slots in the insert are at 3 and 9 o’clock with the pump discharge at 12 o’clock. 4. Install the motor according to instructions in the appropriate motor manual. 5. Attach discharge hose and install pump into the container. Maintenance Disassembly 1.
Reassembly 1. Insert the shaft assembly up through the bottom of the intake tube (item 7) until the end of the shaft sticks out above the top of the pump head. 2. Warm up the seal assembly (item 4) prior to installation by using a heat lamp or soaking them in hot water. This will aid in the ease of proper seal installation. Make sure there are no metal burrs on the pump shaft in the bearing hole location or the coupling half setscrew location that could “cut” the seal during installation. 3.
BTS SPARE PARTS EXPLODED VIEW 7
SPARE PARTS LIST ITEM QTY 1 1 2 1 3* 1 4* 1 5 1 6 1 7 1 8* 3 9 1 10 1 11* 1 12* 1 13 1 DESCRIPTION PART NUMBER COUPLING INSERT J100096 COUPLING HALF 105595-1 BEARING ASSEMBLY W/ ROLL PIN SEAL ASSEMBLY PTFE LOCK WASHER #8 BRASS SCREW #8-32 X 1/4 BRASS PAN HEAD M/S INTAKE TUBE ASSEMBLY 40” 316 STAINLESS STEEL COMPRESSOR PTFE WITH STAINLESS STEEL PIN SPACER SET FEP SHAFT 40” 316 STAINLESS STEEL CENTER BEARING PTFE BOTTOM BEARING PTFE SET SCREW #8-32 X 3/8 STAINLESS STEEL A101672