Datasheet

FTLX6611MCC and FTLX6614MCC T-XFP Product Specification – July 2011 F i n i s a r
© Finisar Corporation 2011 1134335 Rev A01 Page 7
Response timing:
Parameter Min Typ Max Units Ref.
Tx_Dis Assert
De-assert
10
2
us
ms
Rx_LOS Asset
De-assert
100
100
us
us
Mod_NR Asset
De-assert
1
1
ms
ms
Interrupt Asset
De-assert
200
500
ms
us
P_Down/RST Time 10 us
P_Down/RST Asser Delay 100 us
Start-up time (Initialize time) 300 ms 1
1. Time required for transponder to be ready to begin I2C communication with host from a cold start
or a hardware reset condition.
VI. Environmental Specifications
Finisar FTLX6611MCC and FTLX6614MCC XFP transceivers have an operating
temperature range from -5°C to +70°C case temperature.
Parameter Symbol Min Typ Max Units Ref.
Case Operating Temperature T
op
-5 70 °C
Storage Temperature T
sto
-40 85 °C
VII. Regulatory Compliance
Finisar Tunable XFP transceivers are Class 1 Laser Products. They are certified per the
following standards:
Feature Agency Standard Certificate
Number
Laser Eye
Safety
FDA/CDRH CDRH 21 CFR 1040 and Laser Notice 50 9210176
Laser Eye
Safety
TÜV EN 60825-1: 1994+A11:1996+A2:2001
IEC 60825-1: 1993+A1:1997+A2:2001
IEC 60825-2: 2000, Edition 2
R72101686
Electrical
Safety
TÜV EN 60950 R72101686
Electrical
Safety
UL/CSA
CLASS 3862.07
CLASS 3862.87
2283290
(LR 115314)
Copies of the referenced certificates are available at Finisar Corporation upon request.