Datasheet
FTLX1442 Product Specification – July 2009
© Finisar Corporation – July 2009 Rev. B Page 6
Electrical AC Characteristics
(V
CC5
= 4.75 V to 5.25 V, V
CC3
= 3.14 V to 3.47 V, V
CC aps
= 1.152 V to 1.248 V, T
C
= 0°C to 70°C)
Values
Parameter Symbol
min. typ. max.
Unit
XAUI Input AC Characteristics (TXLANE[0..3])
Baud Rate
Fibre Channel
Ethernet
R
XAUIIN
3.1875
3.125
Gbit/s
Baud Rate Tolerance R
TOLXAUI
–100 100 ppm
Differential Input Impedance Z
INXAUI
80 100 120
Differential Return Loss
1)
|S
DD11
| 10 dB
Common Mode Return Loss
1)
|S
CC11
| 6 dB
Input Differential Skew
2)
t
SKEWIN
75 ps
Jitter Amplitude Tolerance
3)
J
XAUITOL
0.65 UI
p-p
XAUI Output AC Characteristics (RXLANE[0..3])
Baud Rate
Fibre Channel
Ethernet
R
XAUIOUT
3.1875
3.125
Gbit/s
Baud Rate Variation R
XAUIVAR
–100 100 ppm
XAUI Eye Mask (far-end) According to IEEE 802.3ae and Fibre Channel 1200-SM-LL-L
Output Differential Skew t
SKEWOUT
15 ps
Output Differential Impedance Z
OUTXAUI
80 100 120
Differential Output Return Loss
4)
|S
22
| 10 dB
Total Jitter
5)
TJ
XAUI
0.35 UI
Deterministic Jitter
5)
DJ
XAUI
0.37 UI
Power-On Reset AC Characteristics
Power-On Reset and TX_ONOFF
Characteristics
According to XENPAK MSA Issue 3.0, 2002-9-18
MDIO I/O AC Characteristics (MDIO; MDC)
MDIO Data Hold Time t
HOLD
10 ns
MDIO Data Setup Time t
SU
10 ns
Delay from MDC Rising Edge to
MDIO Data Change
t
DELAY
300 ns
MDC Clock Rate ƒ
MAX
2.5 MHz
1)
100 MHz to 2.5 GHz, with 100 reference for Differential, 25 reference for Common Mode.
2)
At crossing point.
3)
Per IEEE Std 802.3ae.
4)
312.5 MHz to 625 MHz. See IEEE 802.3ae for 625MHz to 3.125 GHz.
5)
At near-end, No pre-equalization, 1 UI = 320 ps.