Datasheet

FTLX1371 PRELIMINARY Datacom SFP+ Product Specification – July 2008
© Finisar Corporation - July 25, 2008 DRAFT Rev. A3 Page 10
IX. Digital Diagnostic Specifications
FTLX1371D3BCL transceivers can be used in host systems that require either internally or
externally calibrated digital diagnostics.
Parameter Symbol Min Typ Max Units Ref.
Accuracy
Internally measured transceiver
temperature
DD
Temperature
3 ºC
Internally measured transceiver
supply voltage
DD
Voltage
100 mV
Measured TX bias current DD
Bias
10
%
1
Measured TX output power DD
Tx-Power
2 dB
Measured RX received average
optical power
DD
Rx-Power
2 dB
Dynamic Range for Rated Accuracy
Internally measured transceiver
temperature
DD
Temperature
0 80 ºC
Internally measured transceiver
supply voltage
DD
Voltage
3.1 3.5 V
Measured TX bias current DD
Bias
0 20 mA
Measured TX output power DD
Tx-Power
tbd tbd dBm
Measured RX received average
optical power
DD
Rx-Power
tbd 1.5 dBm
Max Reporting Range
Internally measured transceiver
temperature
DD
Temperature
-40 125 ºC
Internally measured transceiver
supply voltage
DD
Voltage
2.8 4.0 V
Measured TX bias current DD
Bias
0 20
mA
Measured TX output power DD
Tx-Power
tbd tbd dBm
Measured RX received average
optical power
DD
Rx-Power
tbd 0 dBm
Notes:
1. Accuracy of Measured Tx Bias Current is 10% of the actual Bias Current from the laser driver to the laser.