Datasheet

FTLX0011D4BNL Laserwire XFP Adapter Product Specification – July 2010
© Finisar Corporation - July 2010 Rev. B1 Page 5
III. Absolute Maximum Ratings
Exceeding the limits below may damage the transceiver module permanently.
Parameter Symbol Min Typ Max Unit Ref.
Maximum Supply Voltage Vcc -0.5 4.0 V
Storage Temperature T
S
-40 85
°C
Relative Humidity RH 0 85 % 1
I. Non-condensing.
IV. Electrical Characteristics (T
OP
= -5 to 85°C, V
CC
= 3.14 to 3.46 Volts)
Electrical characteristics assume a Laserwire cable is inserted into the Adapter port.
Parameter Symbol Min Typ Max Unit Ref.
Supply Voltage Vcc 3.14 3.46 V
Supply Current Icc 400 mA
Transmitter (to Laserwire)
Differential data input swing Vin,pp 120 1000 mV
Receiver (from Laserwire)
Differential data output swing Vout,pp 600 650 800 mV 1
Power Supply Rejection PSR
See Note 2 below 2
Notes
:
1. Into 100Ω differential termination.
2. Per Section 2.7.1 in the XFP MSA Specification INF-8077i
3
.
V. Environmental Specifications
The FTLX0011D4BNL XFP Adapter has an operating temperature range from -5°C to
+85°C case temperature. Note that the Laserwire™ cable has an operating temperature
range of 0°C to +60°C.
Parameter Symbol Min Typ Max Units Ref.
Case Operating Temperature T
op
-5 85 °C
Storage Temperature T
sto
-40 85 °C
VI. Regulatory Compliance
These products are certified by TÜV and CSA to meet the Class 1 eye safety
requirements of EN (IEC) 60825 and the electrical safety requirements of
EN (IEC) 60950. Copies of certificates are available at Finisar Corporation upon request.