Datasheet

FTLF8524E2xNy 2x7 Pin SFF Product Specification – July 2005
Finisar Corporation July 12, 2005 RevG Page 4
IV. Optical Characteristics (T
OP
= -10 to 85 °
°°
°C, V
CC
= 3.0 to 3.6 Volts)
Parameter Symbol Min Typ Max Unit Ref.
Transmitter
Output Opt. Pwr: 50 or 62.5 MMF P
OUT
-9 -2.5 dBm 1
Optical Wavelength
λ
830 860 nm
Spectral Width
σ
0.85 nm
Optical Modulation Amplitude @ 4.25 Gb/s OMA 247
µW
2
Optical Modulation Amplitude @ 2.125 Gb/s OMA
196
µW
2
Optical Modulation Amplitude @ 1.0625 Gb/s OMA
156
µW
2
Optical Rise/Fall Time t
r
/ t
f
90 ps 3
Relative Intensity Noise RIN
-118 dB/Hz
Deterministic Jitter Contribution @ 2.125 Gb/s
TX
DJ
56.5 ps 4
Deterministic Jitter Contribution @ 4.25 Gb/s
TX
DJ
28.2 ps 4
Total Jitter Contribution @ 2.125 Gb/s
TX
TJ
119 ps 5
Total Jitter Contribution @ 4.25 Gb/s
TX
TJ
56.5 ps 5
Mask Margin 2.125 Gb/s 45%
Receiver
Receiver Sensitivity = 1.0625 Gb/s Rx
SENS
-20 dBm 6
Receiver Sensitivity = 2.125 Gb/s Rx
SENS
-18 dBm 6
Receiver Sensitivity = 4.25 Gb/s Rx
SENS
-15 dBm 6
Stressed RX sens. =1.0625 Gb/s 0.055 mW 8
Stressed RX sens. =2.125 Gb/s
0.096 mW 8
Stressed RX sens. =4.25 Gb/s 0.138 mW 8
Average Received Power Rx
MAX
0 dBm
Receiver Elec. 3 dB cutoff frequency 1500 MHz 9
Receiver Elec. 3 dB cutoff frequency 2500 MHz 10
Optical Center Wavelength
λ
C
770 860 nm
Return Loss RL
12 dB
Signal Detect Normal SD
normal
-20 dBm
Signal Detect Fault SD
fault
-30 dBm
Signal Detect Hysteresis
0.5 dB
Notes:
1. Class 1 Laser Safety per FDA/CDRH, EN (IEC) 60825 laser safety regulations.
2. Equivalent extinction ratio specification for Fibre Channel. Allows smaller ER at higher average
power.
3. Unfiltered, 20-80%. Complies with FC 1x and 2x eye mask when filtered.
4. Measured with DJ-free data input signal. In actual application, output DJ will be the sum of input DJ
and
DJ, 10
-12
BER.
5. If measured with TJ-free data input signal, 10
-12
BER. In actual application, output TJ will be given by:
()()
22
DJTJDJTJDJDJTJ
INININOUT
+++=
6. Specifications are for 50 micro-meter or 62.5 micro-meter fiber
7. As measured with 9dB extinction ratio.
8. Measured with conformance signals defined in FC-PI-2 Rev. 7.0 specifications.
9. Rate selectable version in low bandwidth mode.
10. Rate selectable version in high bandwidth mode.