10. Measured with conformance signals defined in FC-PI-2 Rev. 10.0 specifications. Value in OMA.
Measured with PRBS 2
7
-1 at 10
-12
BER
11. Measured with conformance signals defined in FC-PI-2 Rev. 10.0 specifications. Represents
sensitivity based on OMA spec, as corrected to incoming Extinction Ratio of 13 dB (for example, at
5.75dB incoming extinction ratio, an OMA of 0.029 mW corresponds to -16 dBm sensitivity).
Measured with PRBS 2
7
-1 at 10
-12
BER .
12. Rate Selectable version in low bandwidth mode with minimum 9dB extinction ratio.
13. Rate Selectable version in low bandwidth mode.
14. Rate Selectable version in high bandwidth mode.
V. General Specifications
Parameter Symbol Min Typ Max Units Ref.
Data Rate BR 1062 4250 Mb/sec 1
Bit Error Rate BER 10
-12
2
Max. Supported Link Length on
9/125 μm SMF @ 4X Fibre Channel
L
MAX1
10
km
3
Max. Supported Link Length on
9/125μm SMF @ 1X and 2X Fibre
Channel
L
MAX2
10 km 3
Max. Supported Link Length on
9/125μm SMF @ Gigabit Ethernet
L
MAX3
10 km 3
Notes:
1. Gigabit Ethernet and 1x/2x/4x Fibre Channel compliant.
2. Tested with a PRBS 2
7
-1 test pattern.
3. Distances are based on FC-PI-2 Rev. 10.0 and IEEE 802.3 standards.
VI. Environmental Specifications
Finisar 1310nm Industrial Temperature SFP transceivers have an operating temperature
range from –40°C to +85°C case temperature.
Parameter Symbol Min Typ Max Units Ref.
Case Operating Temperature T
op
-40 85 °C
Storage Temperature T
sto
-40 85 °C
VII. Regulatory Compliance
Finisar transceivers are Class 1 Laser Products and comply with US FDA regulations.
These products are certified by TÜV and CSA to meet the Class 1 eye safety
requirements of EN (IEC) 60825 and the electrical safety requirements of EN (IEC)
60950. Copies of certificates are available at Finisar Corporation upon request.