Datasheet
FTL-8519-3D GBIC Product Specification – November 2007 Finisar
© Finisar Corporation November 16, 2007 Rev. A4 Page 7
Parameter Symbol Min Typ Max Units Notes/Conditions
I
2
C Clock Speed 0 100,000 Hz Bus can be driven blind
Accuracy
Internal Transceiver
Temperature
DD
Temperature
-3 +3 °C Measured at controller IC
Internal Transceiver
Supply Voltage
DD
Voltage
-3 +3 % Measured at controller IC
Tx Bias Current DD
Bias
-10 +10 %
Tx Output Power DD
TxPower
-3 +3 dB 100% tested in production
tested at room temp to ±2 dB
Received Average
Power
DD
RxPower
-3 +3 dB 100% tested in production
tested at room temp to ±2 dB
Range
Internal Transceiver
Temperature
DD
Temperature
-40 100 °C
Internal Transceiver
Supply Voltage
DD
Voltage
3.0 6.0 V
Tx Bias Current DD
Bias
0 15 mA
Tx Output Power DD
TxPower
-12 -2 dBm
Received Average
Power
DD
RxPower
-20 1 dBm
Table 9. Digital Diagnostic Accuracy and Range Limits
X. Mechanical Specifications
Finisar GBICs are compatible with the mechanical specifications outlined in the GBIC
Specification Revision 5.5, Section 6
1
.
Insertion, Extraction, and
Retention Forces
Parameter Symbol Min Typ Max Units Notes/Conditions
GBIC insertion F 0 20 Newtons ~4.5 lbs
I
GBIC extraction F 0 15 Newtons ~3.3 lbs
E
GBIC retention F 130 N/A Newtons Straight out ~29.3 lbs
R
Table 10. Insertion, extraction, and retention forces