Parameter Symbol Min Typ Max Units Notes/Conditions
I
2
C Clock Speed 0 100,000 Hz Bus can be driven blind
Accuracy
Internal Transceiver
Temperature
DD
Temperature
-3 +3 °C Measured at controller IC
Internal Transceiver
Supply Voltage
DD
Voltage
-3 +3 % Measured at controller IC
Tx Bias Current DD
Bias
-10 +10 %
Tx Output Power DD
TxPower
-3 +3 dB 100% tested in production
tested at room temp to ±2 dB
Received Average
Power
DD
RxPower
-3 +3 dB 100% tested in production
tested at room temp to ±2 dB
Range
Internal Transceiver
Temperature
DD
Temperature
-40 100 °C
Internal Transceiver
Supply Voltage
DD
Voltage
3.0 6.0 V
Tx Bias Current DD
Bias
0 80 mA
Tx Output Power DD
TxPower
-13.5 1 dBm
Received Average
Power
DD
RxPower
-24 1 dBm