www.finiusa.com OPERATOR’S MANUAL 3 GALLON PORTABLE AIR COMPRESSOR FH3OL195N CUSTOMER SERVICE 1-866-242-4298 Your air compressor has been engineered and manufactured to FINI’s high standard for dependability, ease of operation, and operator safety. When properly cared for, it will give you years of rugged, trouble-free performance. WARNING: To reduce the risk of injury, the user must read and understand the operator’s manual before using this product. Thank you for buying a FINI product.
STOP IMPORTANT STOP DO NOT RETURN TO STORE This unit was fully tested and inspected prior to shipment and will operate properly when instructions are followed. Refer to your owner’s manual for basic troubleshooting. To avoid unnecessary return to the store, simply call Compressor Support toll free for additional assistance. Compressor Support: date for reference. 1-866-242-4298 NOTICE Air Compressor will automatically shut off when maximum PSI is reached.
GENERAL SAFETY RULES Additional safety protection will be required in some environments. For example, the working area may include exposure to a noise level which can lead to hearing damage. The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area. Some environments will require the use of head protection equipment. When required, the employer and user must ensure that head protection marked to comply with ANSI Z89.1 is used.
GENERAL SAFETY RULES Never point any tool toward yourself or others. Keep the exterior of the air compressor dry, clean, and free from oil and grease. Always use a clean cloth when cleaning. Never use brake fluids, gasoline, petroleum-based products, or any strong solvents to clean the unit. Following this rule will reduce the risk of deterioration of the enclosure plastic.
SPECIFIC SAFETY RULES Know your power tool. Read the operator’s manual carefully. Learn its applications and limitations, as well as the specific potential hazards related to this tool. Following this rule will reduce the risk of electric shock, fire, or serious injury. Drain the tank of moisture after each day’s use. If the unit will not be used for a while, it is best to leave the drain valve open until such time as it is to be used.
SYMBOLS Some of the following symbols may be used on this tool. Please study them and learn their meaning. Proper interpretation of these symbols will allow you to operate the tool better and safer. SYMBOL NAME DESIGNATION / EXPLANATION V Volts Voltage. A Amperes Current. Hertz Frequency (cycles per second). Alternating Current Type of current. Class II Construction Double-insulated construction. Wet Conditions Alert Do not expose to rain or use in damp locations.
SYMBOLS The following signal words and meanings are intended to explain the levels of risk associated with this product. SYMBOL SIGNAL MEANING DANGER: Indicates an imminently hazardous situation, which, if not avoided, will result in death or serious injury. WARNING: Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury. CAUTION: Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury.
ELECTRICAL SPEED AND WIRING EXTENSION CORDS The no-load speed of the electric motor varies by model and specification. The motor speed is not constant and decreases under a load or with lower voltage. For voltage, the wiring in a shop is as important as the motor’s horsepower rating. A line intended only for lights cannot properly carry a power tool motor. Wire that is heavy enough for a short distance will be too light for a greater distance.
GLOSSARY OF TERMS Air Filter Porous element contained within a metal or plastic housing attached to the compressor cylinder head which removes impurity from the intake air of the compressor. Pressure Switch Automatically controls the on/off cycling of the compressor. It stops the compressor when the cut-off pressure in the tank is reached and starts the compressor when the air pressure drops below the cut-in pressure. Air Tank Cylindrical component which contains the compressed air.
FEATURES PRODUCT SPECIFICATIONS Running Horsepower ................................................ 1.0 HP Air Tank Capacity........................................................ 3 gal. Air Pressure ....................................................150 PSI max. Air Delivery ......................................... 2.5 SCFM @ 90 PSI Duty Cycle ...........S3/50% - 5 minutes ON and 5 minutes OFF Fig. 2 Lubrication .............................................................. Oil-Free Gauges ..........
FEATURES KNOW YOUR AIR COMPRESSOR AIR COMPRESSOR PUMP See Figure 2. Before attempting to use this product, familiarize yourself with all operating features and safety rules. Your air compressor features permanently lubricated bearings. To compress air, the piston moves up and down in the cylinder. On the down stroke, air is drawn in through the air intake valve while the exhaust valve remains closed.
ASSEMBLY MANUAL ON/OFF SWITCH ATTACHING HOSE Insert the hose into the quick coupler already installed on the compressor (Fig. 3). PRESSURE REGULATOR KNOB REGULATOR PRESSURE GAUGE WARNING: Do not attach any tools to the open end of the hose until start-up has been completed. QUICK COUPLER Firmly grasp the open end of the hose; hold facing away from yourself and others. TANK PRESSURE GAUGE BREAKING IN THE PUMP See Figures 3 - 5. Fig. 3 Check and tighten all bolts, fittings, etc.
OPERATION APPLICATIONS WARNING: Air compressors are utilized in a variety of air system applications. Match hoses, connectors, air tools, and accessories to the capabilities of the air compressor. You may use this tool for purposes listed below: Operating air powered tools requiring less than 2.5 SCFM @ 90 PSI. Powering pneumatic nail guns, inflating tires, cleaning / blowing with pressurized air. Do not allow familiarity with tools to make you careless.
OPERATION DRAINING THE TANK See Figure 8. To help prevent tank corrosion and keep moisture out of the air used, the tank of the compressor should be drained daily. To drain: Verify that the compressor is turned off. Holding the handle, tilt the compressor toward the drain valve so that it’s set in a lower position. Open the drain valve by rotating it ¼ turn counterclockwise. Keep the compressor tilted until all moisture has been removed. Drain moisture from tank into a suitable container.
MAINTENANCE Inspect the tank yearly for rust, pin holes, or other imperfections that could cause it to become unsafe. WARNING: When servicing, use only identical replacement parts. Use of any other parts may create a hazard or cause product damage. Avoid using solvents when cleaning plastic parts. Most plastics are susceptible to damage from various types of commercial solvents and may be damaged by their use. Use clean cloths to remove dirt, dust, oil, grease, etc.
TROUBLESHOOTING Problem The compressor does not run. Possible Cause Loss of power or overheating. There is no electrical power being supplied to compressor or the power switch is in the OFF position. A fuse has blown at the power supply. A breaker has tripped at the power supply. Thermal overload open. The pressure switch is bad. Tank is full of air. The motor hums, but does not run or runs slowly. The fuses blow or the circuit breaker trips repeatedly. The voltage from the power supply is low.
REPLACEMENT PARTS LIST 17
REPLACEMENT PARTS LIST The model number will be found on a plate attached to air tank. Always mention the model number in all correspondence regarding your PORTABLE AIR COMPRESSOR or when ordering replacement parts. KEY NO.
REPLACEMENT PARTS LIST 19
REPLACEMENT PARTS LIST Always mention the model number when ordering replacement parts. KEY NO.
WARRANTY FINI AIR COMPRESSOR LIMITED TWO-YEARS WARRANTY This product is manufactured by Nu Air Shanghai factory, Ltd, based in Shanghai, China or its North American Operations, FINI USA Corp., Rock Hill, SC, or by other FINI Operations worldwide. The trademark is licensed from FINI. All warranty communications about this FINI model should be directed to air compressor support at (toll free) 1-866-242-4298.