Installer Guide
Enhanced Security with l AdapTec-X is a basic accessory suggested for FingerTec access control systems. It enhances access control functionalities as well as eases the installation process with its encrypted communication and secure I/O expansion features and all these features are compressed into a sleek casing to deliver a cost effective solution.
UNDERSTANDING ADAPTEC-X FUNCTIONS Enhanced Security with Encrypted Signals It supports FingerTec encrypted 26-bit Wiegand communication output; providing enhanced security level for extra protection. Power Up Terminals & Door Lock Systems A single AdapTec-X can support a maximum of 2 units of FingerTec terminals and 2 sets of door lock accessories such as the EM lock and drop bolt in one single system installation.
UNDERSTANDING THE TECHNICAL SPECIFICATIONS PHYSICAL APPEARANCE Surface finishing Acrylonitrile Butadiene Styrene (ABS) Dimension, mm 85 x 96 x 33 Weight, kg 0.1 CPU High Performance RISC CPU Power input 12VDC 3A Power output 12VDC 3A Backup Power system UPS or 12VDC Rechargeable battery Input signal 26-bit FingerTec encrypted Weigand signal Output signal 12VDC 0.
UNDERSTANDING THE DESIGN Door lock timer 1 2 3 4 LED status indicator Input/output connectors Input/output connectors 1 These cables connect to the DC12V power from the power supply. 2 These cables connect to a DC12V rechargeable backup battery. During a power failure, the backup battery will power up AdapTec-X. 3 These are the power output ports for AdapTec-X. Refer to the wiring diagram for details. 4 These are the Wiegand data input ports for the FingerTec terminals.
OTHER FEATURES You will find a buzzer, 3 LED indicators, and a door lock timer on the board. Check and set each of them accordingly after powering up the system. 1 2 3 4 1 You will hear the buzzer beep to indicate • Unlocked Door Door is unlocked and access is granted (during verification or pressing push release button). • Over Voltage (After startup) Over voltage of power input (Stop the power supply to the system immediately and check the input voltage, consult support@fingertec.
DETAILS OF WIRING AdapTec-X supports 2 types of installations, Convenient or Secure. You can select between modes by applying different wiring arrangements during installation. Under Convenient mode, AdapTec-X will unlock doors immediately after receiving responses from FingerTec devices. This feature is supported by all FingerTec models. For installations using Secure mode, there will be a 1s time delay when unlocking the door after verification at FingerTec devices.
WIRING DIAGRAMS 1 CONVENIENT INSTALLATION AdapTec-X Regulated Battery Tamper Siren Input SW Out 0V +14.5V 0V 12V EM Lock EM Lock + __ OV Siren Mute Exit SW OV Data D1 D0 GND 12V Exit Button NO Emergency 3 Break Glass 2 Emergency Break Glass +12 Out GND 2 3 Connection Points WIRING DIAGRAMS 2 SECURE INSTALLATION AdapTec-X Regulated Battery Tamper Siren Input SW Out 0V +14.
CONNECTING ADAPTEC-X TO AN ALARM SIREN For all FingerTec door access control models, there is a security button behind the terminal. During normal operation, the security button is compressed and once the terminal is dismantled, the button will be released and a “System broken” message will appear onscreen. During the release of the button, the terminal will output an alarm signal. However, no alarm sound will be emitted if the terminal is not equipped with an external siren.
WIRING DIAGRAMS 4 ALARM SIREN • Face ID 2, Q2i and i-Kiosk 100 Plus AdapTec-X Regulated Battery Tamper Siren Input SW Out 0V +14.5V 0V 12V EM Lock + --Alarm Siren +12 Out OV Siren Mute Exit SW OV Data D1 D0 Siren Mute Button COM2 NO2 Connection Points GND 12V Remark: • Set Auto Alarm in terminal to N. • Menu > Options > Sys Opt > Adv Opt > Auto Alarm > N. Deactivating the Alarm Siren: 1. At the terminal, press Menu and select Turn Off Alarm to turn off the alarm siren. 2.
UNDERSTANDING ADAPTEC-X INSTALLATION FOR • Wooden Door or Glass Door The diagrams below only highlights the use of an EM lock during installation. You may opt to use a dropbolt/deadbolt/door strike instead. Please consult a qualified technician/installer before proceeding with the installation. WALL 1 2 Back Steel Plate Screws 3 4 feet / 1.2 meter (recommended) 1 To install FingerTec AC900/R2 on a wall, drill 5 holes as shown.
Wooden Doorframe Glass Doorframe 1 U-Bracket 2 1 Allen Key Screws Silver Nut Steel Bar Steel Bar 2 Allen Key Screw 1 Allen Key Screws 2 Philip Screw Wooden Door 1 Drill 3 holes on the wooden door. 2 Place the Steel Bar on the door. Insert the Silver Nut on one side and the Allen Key Screw on the other side. Tighten the screw to lock the Steel Bar onto its position. Glass Door 1 Lodge the U-Bracket into the upper edge of the glass doorframe.
1 Drill 4 holes on the wooden frame. Tighten the 4 screws to fix the Aluminum Plate properly on the doorframe. Doorframe Screws Magnet Allen Key Screws Aluminum Plate 1 1 2 3 2 Use the Allen Key to tighten the 2 screws at the bottom of the Magnet. The Magnet will stick to the Aluminum Plate when the screws are tightened. 3 Use the Allen Key to tighten the other 2 screws on the sides of the Magnet.
FINGERTEC ACCESSORIES For more accessories, go to accessory.fingertec.com.
NOTE: Details in this manual are subject to change. Check http://product.fingertec.com for latest product information. © 2000-2014 FingerTec Worldwide Limited. All rights reserved. • Printed in Malaysia.