User Manual

33
Options 6
Comm Opt
Log Opt
4 Auto test
Options 6
Log Opt
Auto test
4 Sys Info
AUTO TEST
This option allows fingerTec® resellers/technician to run test to the
reader to identify any error. Please do not run test without guidance/su-
pervision from fingerTec® resellers/technicians.
SYSTEM INFO
User may check the information stored in the reader under this option.
The information includes:
User Cnt to show total of users in reader
FP Cnt to show total of fingerprints templates in reader
Att Log to show total of attendance log in reader
Admin Cnt to show total of administrators in reader
Pwd Usr to show total of password users in reader
Super Logs this item is used by FingerTec® technicians for testing purpose
Free Space Inf to show empty spaces which are available in reader
Dev Info FPCnt (100) to show the number of fingerprints templates stored in reader
AttLog (10k) to show the amount of attendance log could bestored in reader
Super Logs for testing purpose
Manu time manufacturing time of reader
Serial Num serial number of reader
Manufacturer name of manufacturer
Device name name of reader
Alg Version to show the algorithm version use by the reader
Firmware ver to show the firmware version use by the reader