6.2 Measurement Specifications
The following table provides specifications for the measured parameters.
Measurement
Range
Accuracy
Resolution
Indoor Temperature
-14 to 140 °F
-10 to 60 °C
± 1.8 °F
± 1 °C
0.1 °F
0.1 °C
Outdoor Temperature
-40 to 140 °F
-40 to 60 °C
± 1.8 °F
± 1 °C
0.1 °F
0.1 °C
Indoor Humidity
10 to 99 %
± 5% (only
guaranteed between
20 to 90%)
1 %
Outdoor Humidity
10 to 99%
± 5% (only
guaranteed between
20 to 90%)
1 %
Barometric Pressure
8.85 inHg to 32.48
inHg
300 hpa to 1100 hpa
± 0.09 inHg
±3 hpa (only
guaranteed between
700 to 1100hpa)
0.01 inHg
0.1hpa
Figure 18
6.3 Power Consumption
Base station : 5V DC adaptor (included)
3 x AAA 1.5V Batteries (not included)
Remote sensor : 2 x AAA Batteries (not included)
Battery life: About 12 months for base station
About 12-24 months for thermometer-hygrometer sensor (use lithium batteries in cold
weather climates)
7 Troubleshooting Guide
Problem
Solution
Wireless remote (thermo-hygrometer) not
reporting in to console.
There are dashes (--.-) on the display
console.
If any of the sensor communication is lost, dashes (--.-)
will be displayed on the screen. To reacquire the signal,
reference 4.8.7.
The maximum line of sight communication range is 300
feet and 100 feet under most conditions. Move the sensor
assembly closer to the display console.
If the sensor assembly is too close (less than 5’), move
the sensor assembly away from the display console.